NOK Judgement LED tube
When an error occurs, OK / NOK Judgement LED tube flashes in red.
Please check the error display on UEC-4800 controller / UCC-100Z coordinator.
・
Error List (Display type shows Error on the monitor screen.)
Error
Display
Content
Reference / Measure(s)
ZERO ERROR
ERR01
Controller display :
ZERO check error at start up by grip switch
CAL ERROR
ERR02
Controller display :
CAL check error at start-up by grip switch
SETUP ERROR
ERR03
Controller display :
Setting range interlocking
TORQUE LOW
TRQNOK
(
+
Value)
Torque Value
<
Torque Low
TORQUE HIGH
TRQNOK
(
+
Value)
Torque Value
>
Torque High
PULSE LOW
PLSNOK
(
+
Value)
Pulse Count < Pulse Low
PULSE HIGH
PLSNOK
(
+
Value)
Pulse Count > Pulse High
FREE RUN ERROR
NOKFRE (
+
Value)
Free Run Angle Value < Free Run Angle
ANGLE LOW
DEGNOK
(
+
Value)
Angle Value < Angle Low
ANGLE HIGH
DEGNOK
(
+
Value)
Angle Value > Angle High
INITIAL ERROR
Elapsed time from START to CUT is shorter than
Initial Error Timer.
(Torque reaches CUT before Initial Error timer is
up.)
●
Double hit error
●
If the error appears with the
normal tightening process, review
setting parameters.
CYCLE ERROR
Elapsed time from START to CUT is longer than
Cycle Error Timer.
(Torque does not reach CUT before Cycle Error
timer is up.)
●
Review workpiece condition.
●
Review setting parameters.
INCOMPLETE JOB
ERROR
Tool stops tightening before reaching CUT torque.
(e.g. Fingers off from trigger while tightening)
●
Review Judgement Delay Timer
●
Check tool condition.
●
Do not release fingers from trigger
before tool stops automatically.
CPU ERROR
ERR10
Controller display :
CPU Thermal Error
MOTOR ERROR
ERR11, ERR32
Controller display :
Motor System Error
ZIGBEE ERROR
ERR12
Controller display :
ZigBee Communication Error
SENSOR ERROR
ERR13, ERR14
Controller display :
Sensor Communication Error
BATTERY ERROR
ERR15
Controller display :
Over-discharged battery, Battery Thermal Error
21
Summary of Contents for UBX-AF Series
Page 20: ...Exploded View 18...