background image

 

 

Break 

Do not block the air vents. 

 

5.3    Cooling Ventilator 

        In case of the motor temperature is below 40°C, the cooling ventilator 

operates only when the trigger is pulled. When the motor temperature 

exceeds 40°C, the ventilator continues to operate until the motor temperature 

drops below 40°C. After the ventilator stops its operation, 

pull the trigger again so that the ventilator operates 

with the above logic. 

 

 

         

Do not block the air vents when the tool is in use. 

        Insufficient ventilation may result in heat or smoke. 

 

5.4    Overheating Protection 

Overheating protection functions to disable the tool 

when the motor heats up due to exceeding duty cycle. 

OK/NOK Judgement LED tube turns red and disables the tool 

until the red LED turns off. 

Once the red LED blinks, do not use the tool for 30 minutes at least until the motor temperature has 

cooled down. Do not detach and re-attach the battery or replace the battery with another one while 

the red LED blinks.

 This resets the heating protection even with the overheating motor.

 

 

Guidance of Suitable Applications for UBX-AF series 

Example : UBX-AF700Z 

Working condition : (the same as the durability test condition, See P9. Operating Cycle per Full-Charge) 

Bolt Size --- M12 

Fastening Time per Fastener --- approx. 0.5 sec. 

UBX-AF700Z will be able to fasten 9 fasteners per minute under the above working condition. 

Mathematical Expression ------ 0.5 sec./fastener 

×

  9 fasteners/min. = 4.5 sec./min. 

         

 

With UBX-AF700Z, overheating protection will not function as long as the tool tightens M12 fasteners for 

total 4.5 sec. per minute, see below. 

 

 

 

 

 

          Softer joints (i.e. longer fastening time per fastener) will require less aggressive fastening cycles. 
 

5.5    After Daily Use 

When the working day is over, detach the battery from the tool to avoid unexpected 

operation nor electric shock. 

Cover the battery pack for dust / rubbish adhesion prevention. 

 

16 

Cooling Ventilator 

Colour

 

     

                         

Status 

Green

             

              Tightening OK

                                   

Red                     

Under Heating Protection 

OK / NOK Judgement LED Tube

 

Battery  Pack  Cover 

Green LED and OK buzzer confirm OK tightening. 

0.5 sec. each 

0.5 sec. each 

1-minute cycle 

 

Summary of Contents for UBX-AF Series

Page 1: ...nd specifications provided with this power tool before installing operating repairing maintaining changing accessories on or working near the power tool Failure to follow all instructions in this manu...

Page 2: ...ical Specifications 3 2 1 Tool Technical Specifications 3 2 2 ZigBee Specifications 4 Operation 4 1 Socket 4 2 Direction Of Rotation 4 3 LED Work Light 4 4 Torque Setting 4 5 Preparation For Operation...

Page 3: ...clean and well lit Cluttered or dark areas invite accidents Do not operate power tools in explosive atmospheres such as in the presence of flammable liquids gases or dust Power tools create sparks whi...

Page 4: ...e both hands available Remove any adjusting wrench before turning the power tool on A wrench left attached to a rotating part of the power tool may result in personal injury Do not overreach Keep prop...

Page 5: ...d could result in a hazardous situation Keep handles and grasping surfaces dry clean and free from oil and grease Slippery handles and grasping surfaces do not allow for safe handling and control of t...

Page 6: ...or at temperatures outside the specified range may damage the battery and increase the risk of fire Keep the battery and charger dry and away from water or any liquid as it may cause a short circuit...

Page 7: ...cian immediately Hold the power tool with a light but safe grip taking account of the required hand reaction forces The risk from vibration is generally greater when the grip force is higher Wear warm...

Page 8: ...with low noise low vibration and low torque reaction Vibration total value 2 5m s2 Sound pressure level 73dB 2 Battery Powered Cordless Flexible UBX AF tool provides you with flexible production line...

Page 9: ...of an emergency such as earthquake Familiarise yourself with the followings to install and fix the system firmly 1 5 1 Place To Install 1 Install the system inside a building Never expose the system t...

Page 10: ...DC14 4V DC14 4V DC18 0V Capacity 2 0Ah 3 0Ah 2 0Ah 4 0Ah 5 0Ah Usable Charging Time Approx 35 min Approx 35 min Approx 35 min Approx 50 min Approx 65 min Full Charging Time Approx 40 min Approx 40 mi...

Page 11: ...d however it depends on working conditions When number of fasteners per full charge becomes about a half of the new battery condition replace the battery with a new one Replace only with the battery d...

Page 12: ...Tool Battery Battery Pack obtain locally Wireless ZigBee Type PC for ID Setup not supplied with the product USB Serial Cable Option 910 396 0 UCC 100Z Coordinator f w ZigBee Receiver UBX AFZ Tool f w...

Page 13: ...in use System Configuration Setup PC UCC 100Z Front panel UCC 100Z Rear panel Sequencer I O PLC PC Hub Socket Outlet UBX AFZ Tool Power Cable RS232C Cable 910 219 0 PC UCC 100Z etc ZigBee Wireless co...

Page 14: ...s that the battery pack is nearly depleted and needs recharging immediately Off EMPTY Battery level 0 Note Tool will stop after completion of the last tightening when the battery power indicator turns...

Page 15: ...o battery pack Note4 Settable combination of Motor Power Current Level and Motor Speed Range Current Level 1 13 1300min 1 48 4800min 1 Current Level 2 17 1700min 1 48 4800min 1 Current Level 3 21 2100...

Page 16: ...ket and anvil by depressing retainer pin 4 2 Direction Of Rotation 4 3 LED Work Light Pull the trigger and the LED work light illuminates work area Never look directly into the LED work light while it...

Page 17: ...mended to minimise torque down and wobbling 3 Pull the trigger firmly to operate the tool If the trigger is not pulled correctly the tool may not be stopped automatically 4 Torque drop can be seen whe...

Page 18: ...le the red LED blinks This resets the heating protection even with the overheating motor Guidance of Suitable Applications for UBX AF series Example UBX AF700Z Working condition the same as the durabi...

Page 19: ...ne third of the bearing with high quality grease Multemp PS No 2 see the right table or equivalent Overhaul It is recommended that after every 5 000 000 pulses or 6 months replace the pulse fluid It i...

Page 20: ...Exploded View 18...

Page 21: ...Noise Sheet 1 Motor Communication Cable Assembly 50 Fan Assembly 1 51 Nylon Mesh 1 52 Mesh Plate 1 53 Grip Switch 1 54 Grip Switch Plate 1 55 Control Board Assembly 1 60 ZigBee Board Assembly 1 61 Dip...

Page 22: ...eed Excessive load Repair or replace Review parameters for Current and Speed Load reduction Ventilator does not work Breakage of ventilator Breakage of wire for ventilation inside the tool Repair or r...

Page 23: ...e Value Angle High INITIAL ERROR Elapsed time from START to CUT is shorter than Initial Error Timer Torque reaches CUT before Initial Error timer is up Double hit error If the error appears with the n...

Page 24: ...STATES RELATING TO THE MAKING AVAILABLE ON THE MARKET OF RADIO EQUIPMENT Harmonised Standards EN 62841 1 2015 EN 62841 1 1 2015 AC 2015 EN 62841 2 2 2014 EN 62841 2 2 2014 AC 2015 EN ISO 28927 2 2009...

Page 25: ......

Page 26: ...Distributed by For further information contact your nearest URYU distributor or URYU Japan International Dept 81 0 6 6973 9415 81 0 6 6972 0346 uryuair uryu co jp UBX AF 2020 11 12...