background image

3.2    Technical Specifications 

3.2.1 Tool Technical Specifications 

Item / Model 

UBX-AF500Z 

UBX-AF600Z 

UBX-AF700Z 

Bolt Capacity 

M6-M8 

M8-M10 

M8-M12 

Torque Range

 

Nm 

5.0

20.0 

15.0

40.0 

25.0

60.0 

Fastening Cycle 

Note 1

 

 

11 fasteners / min. 

10 fasteners / min. 

9 fasteners / min. 

Free Speed

 Note 2 

min

-1

 

1000 

– 3600 

1000 - 4800 

Drive Shank Size 

mm 

9.5Sq 

Overall Length 

mm 

219 

Weight 

Note 3 

kg 

1.83(1.53) 

1.88(1.53) 

1.93(1.58) 

Sound Pressure Level (L

pA

dB(A) 

<70 

73 

72 

Sound Uncertainty 

dB(A) 

Vibration Total Value (A

hd

m/s

<2.5 

Vibration Uncertainty (

K

m/s

0.59 

0.60 

0.61 

Reaction Moment 

Nm 

0.8 

1.0 

Trigger Force 

8.0 

Battery Voltage (DC) 

10.8 

14.4 

Motor Speed

 Note 4 

min

-1

 

Initial Speed (up to START torque) 
Settable per 100 min

-1

 increments 

from 1000 min

-1 

to 3600 min

-1

 

Initial Speed (up to START torque) 
Settable per 100 min

-1

 increments from 1000 min

-1 

to 4800 min

-1

 

Speed (from START to CUT torque) 
Settable per 100 min

-1

 increments 

from 1300 min

-1

 to 3600 min

-1

 

Speed (from START to CUT torque) 
Settable per 100 min

-1

 increments from 1300 min

-1

 to 4800 min

-1

 

Motor Power 

Note 4

 

(Current Level) 

 

Settable in 2 steps (till and after START Torque) from 4 levels  

IEC62841-1 and IEC62841-2-2 are applied. Protection against electric shock is Class I. 

Note

1

…Fastening Condition : Fastening Time Approx. 0.5 sec/fastener at ambient temperature of 18 °C (64.4°F) 

Note

2

…Free speed increases in 3 steps, 500min

-1

 

→ 1000min

-1

 

→ Initial Speed Value 

Note

3

…Weight f/w 2.0Ah battery pack (see P.8). Value inside (    ) shows weight w/o battery pack. 

Note

4

…Settable combination of Motor Power (Current Level) and Motor Speed Range 

Current Level 1 : 13 (1300min

-1

) ~ 48 (4800min

-1

), Current Level 2 : 17 (1700min

-1

) ~ 48 (4800min

-1

Current Level 3 : 21 (2100min

-1

) ~ 48 (4800min

-1

), Current Level 4 : 25 (2500min

-1

) ~ 48 (4800min

-1

 
 
 
 
 

 
 
 
 
 
 
 
 
 

 

3.2.2 ZigBee Specifications 

Frequency 

2.4GHz (2.405 - 2.48Hz 16ch) 

Output 

10mW 

Modulation and Communication System 

Offset phase orthogonal modulation system 

Spread System 

Direct spread spectrum communication system 

Communication Distance 

Radius of approx. 20m 

*Note

 

ID Setting 

7 Bit Dip Switch (128 ways) 

*NOTE: The communication may not be established at the place where radiation noise such as electric welding exists. 

If there is a place where the communication is not established even in a short distance between the transmitter   
and the receiver, there may be a dead point which is generated by a reflected wave. 

 

 

 

13 

These  declared  sound  and  vibration  values  given  in  the  above  table  were  obtained  by  laboratory   
type  testing  in  accordance  with

 

EN  62841-1  for  sound  levels

  and 

ISO  28927-2

 

for  vibration   

values

  and  are  not  adequate  for  use  in  risk  assessments.    Values  measured  in  individual  work   

places  may  be  higher  than  the  declared  values.    The  actual  exposure  values  and  risk  of  harm   
experienced  by  an  individual  user  are  unique  and  depend  upon  the  way   the  user  works,  the   
workpiece  and  the  workstation  design,  as  well  as  u ppon  the  exposure  time  and  the  physical   
condition of the user. 

 

We,  URYU  SEISAKU,  LTD.,  cannot  be  held  liable  for  the  consequences  of  using  the  declared    
values, instead of values reflecting the actual exposure, in an individual risk assessment in a work   
place situation over which we have no control. 

Summary of Contents for UBX-AF Series

Page 1: ...nd specifications provided with this power tool before installing operating repairing maintaining changing accessories on or working near the power tool Failure to follow all instructions in this manu...

Page 2: ...ical Specifications 3 2 1 Tool Technical Specifications 3 2 2 ZigBee Specifications 4 Operation 4 1 Socket 4 2 Direction Of Rotation 4 3 LED Work Light 4 4 Torque Setting 4 5 Preparation For Operation...

Page 3: ...clean and well lit Cluttered or dark areas invite accidents Do not operate power tools in explosive atmospheres such as in the presence of flammable liquids gases or dust Power tools create sparks whi...

Page 4: ...e both hands available Remove any adjusting wrench before turning the power tool on A wrench left attached to a rotating part of the power tool may result in personal injury Do not overreach Keep prop...

Page 5: ...d could result in a hazardous situation Keep handles and grasping surfaces dry clean and free from oil and grease Slippery handles and grasping surfaces do not allow for safe handling and control of t...

Page 6: ...or at temperatures outside the specified range may damage the battery and increase the risk of fire Keep the battery and charger dry and away from water or any liquid as it may cause a short circuit...

Page 7: ...cian immediately Hold the power tool with a light but safe grip taking account of the required hand reaction forces The risk from vibration is generally greater when the grip force is higher Wear warm...

Page 8: ...with low noise low vibration and low torque reaction Vibration total value 2 5m s2 Sound pressure level 73dB 2 Battery Powered Cordless Flexible UBX AF tool provides you with flexible production line...

Page 9: ...of an emergency such as earthquake Familiarise yourself with the followings to install and fix the system firmly 1 5 1 Place To Install 1 Install the system inside a building Never expose the system t...

Page 10: ...DC14 4V DC14 4V DC18 0V Capacity 2 0Ah 3 0Ah 2 0Ah 4 0Ah 5 0Ah Usable Charging Time Approx 35 min Approx 35 min Approx 35 min Approx 50 min Approx 65 min Full Charging Time Approx 40 min Approx 40 mi...

Page 11: ...d however it depends on working conditions When number of fasteners per full charge becomes about a half of the new battery condition replace the battery with a new one Replace only with the battery d...

Page 12: ...Tool Battery Battery Pack obtain locally Wireless ZigBee Type PC for ID Setup not supplied with the product USB Serial Cable Option 910 396 0 UCC 100Z Coordinator f w ZigBee Receiver UBX AFZ Tool f w...

Page 13: ...in use System Configuration Setup PC UCC 100Z Front panel UCC 100Z Rear panel Sequencer I O PLC PC Hub Socket Outlet UBX AFZ Tool Power Cable RS232C Cable 910 219 0 PC UCC 100Z etc ZigBee Wireless co...

Page 14: ...s that the battery pack is nearly depleted and needs recharging immediately Off EMPTY Battery level 0 Note Tool will stop after completion of the last tightening when the battery power indicator turns...

Page 15: ...o battery pack Note4 Settable combination of Motor Power Current Level and Motor Speed Range Current Level 1 13 1300min 1 48 4800min 1 Current Level 2 17 1700min 1 48 4800min 1 Current Level 3 21 2100...

Page 16: ...ket and anvil by depressing retainer pin 4 2 Direction Of Rotation 4 3 LED Work Light Pull the trigger and the LED work light illuminates work area Never look directly into the LED work light while it...

Page 17: ...mended to minimise torque down and wobbling 3 Pull the trigger firmly to operate the tool If the trigger is not pulled correctly the tool may not be stopped automatically 4 Torque drop can be seen whe...

Page 18: ...le the red LED blinks This resets the heating protection even with the overheating motor Guidance of Suitable Applications for UBX AF series Example UBX AF700Z Working condition the same as the durabi...

Page 19: ...ne third of the bearing with high quality grease Multemp PS No 2 see the right table or equivalent Overhaul It is recommended that after every 5 000 000 pulses or 6 months replace the pulse fluid It i...

Page 20: ...Exploded View 18...

Page 21: ...Noise Sheet 1 Motor Communication Cable Assembly 50 Fan Assembly 1 51 Nylon Mesh 1 52 Mesh Plate 1 53 Grip Switch 1 54 Grip Switch Plate 1 55 Control Board Assembly 1 60 ZigBee Board Assembly 1 61 Dip...

Page 22: ...eed Excessive load Repair or replace Review parameters for Current and Speed Load reduction Ventilator does not work Breakage of ventilator Breakage of wire for ventilation inside the tool Repair or r...

Page 23: ...e Value Angle High INITIAL ERROR Elapsed time from START to CUT is shorter than Initial Error Timer Torque reaches CUT before Initial Error timer is up Double hit error If the error appears with the n...

Page 24: ...STATES RELATING TO THE MAKING AVAILABLE ON THE MARKET OF RADIO EQUIPMENT Harmonised Standards EN 62841 1 2015 EN 62841 1 1 2015 AC 2015 EN 62841 2 2 2014 EN 62841 2 2 2014 AC 2015 EN ISO 28927 2 2009...

Page 25: ......

Page 26: ...Distributed by For further information contact your nearest URYU distributor or URYU Japan International Dept 81 0 6 6973 9415 81 0 6 6972 0346 uryuair uryu co jp UBX AF 2020 11 12...

Reviews: