3.2 Power Supply
The Ursalink UC1114 has a terminal block interface where a power supply can be connected. The
power supply should have the following specifications:
Output Voltage: 12V nominal
Output Current: 0.5A
Installation:
A suitable power supply comes with the product.
For industrial applications, it is advised that the Ursalink UC1114 should be installed into its own
metal housing and be powered from a separate power supply (as opposed to sharing one with
other equipment) .
Please Note: While the Ursalink UC1114 has fairly rugged internal power supply circuitry, no
special provision for lightning protection is well in place. If the Ursalink UC1114 is used in an area
where thunderstorm is about to occur, it is advisable to use a commercially available lightning
suppressor (the same applies to inputs or outputs connected to wires longer than 2 or 3 meters).
The guarantee does not cover damage resulting from lightning strikes! The Ursalink UC1114 can
operate reliably from voltages in the range of 5 to 24 VDC.
3.3 Micro USB Port
The Ursalink UC1114 provides a micro USB port to connect to a PC via USB cable, which allows
the PC to configure the unit.