background image

Summary of Contents for UC1114

Page 1: ......

Page 2: ...WAN 11 4 3 1 Basic 11 4 3 2 Channel 13 4 3 3 Advanced 14 4 4 Command 16 4 4 1 Read Command from Device 16 4 4 2 Open a Command File 16 4 4 3 Save the Command to Device 16 4 4 4 Save the Command as Fil...

Page 3: ...alarm condition brings attention to engineering personnel immediately The output can be connected with an alarm indication device such as a light or horn The device can give immediate response to the...

Page 4: ...cally noisy equipment DO NOT install the Ursalink UC1114 into a metal enclosure unless an antenna is mounted on the outside of the enclosure Parameter Item Reference Scope Antenna 50 SMA Antenna Inter...

Page 5: ...equipment Please Note While the Ursalink UC1114 has fairly rugged internal power supply circuitry no special provision for lightning protection is well in place If the Ursalink UC1114 is used in an a...

Page 6: ...C1114 will take action if you have pre configured related command Terminal IN1 or IN2 is internally pulled high Leaving the connection open or connecting it to 0 1 V which will indicate an Input De ac...

Page 7: ...e internally connected to a 3 Amp SPDT relay OUT_NC Normally Closed OUT_COM Common OUT_NO Normally Open Maximum Current 3 Amp Maximum Voltage 250VAC 30 VDC 4 Configuration 4 1 Configuration via PC Fol...

Page 8: ...can create a new setup import an existing setup from your PC or retrieve the current setup from the Ursalink UC1114 4 1 1 Serial Port Settings When the Ursalink ToolBox displays Connecting to device p...

Page 9: ...sion Null Login Password Enter the correct password to login Null Baud Rate Select from 9600 57600 115200 57600 Data Bits Select from 5 7 8 8 Parity Bits Select from Even Odd None None Stop Bits Selec...

Page 10: ...RSSI SNR Show the RSSI SNR of received packet Channel Show the the channel currently used by the device to send packets Rx2DR Show the RX2 datarate which used for the RX2 receive window Input Show th...

Page 11: ...receive data 55 Join Type Select from OTAA and ABP OTAA Over the Air Activation For over the air activation end devices must follow a join procedure prior to participating in data exchanges with the n...

Page 12: ...used for derive the Application Session key 5572404c696e6b4c 6f52613230313823 ABP Settings Item Description Default Network ID Network identifier NwkID is used to separate addresses of territorially o...

Page 13: ...erver and the end device to encrypt and decrypt the payload field of application specific data messages 5572404c696e 6b4c6f5261323 0313823 4 3 2 Channel On this page you can view all the supported LoR...

Page 14: ...mand Disabled Whatever how the signal quality is the Network Server will not adjust the datarate of UC1114 Disabled TXPower The TX transmit power setting is used to control the transmission power of t...

Page 15: ...e Enable Duty Cycle Number of minutes in sliding windows for duty cycle restrictions 0 The 0 means using the standard Duty Cycle which is specified in the LoRaWAN Regional Parameters Uplink Frame Coun...

Page 16: ...nd file from your PC with following steps 1 Click Open a command File 2 Select the command file 4 4 3 Save the Command to Device You can click Save the Command to Device to save the command having bee...

Page 17: ...tion will only be triggered during certain period within a day or only if certain input output conditions are met The user can enter the edit page by clicking or delete the command by clicking 4 5 1 S...

Page 18: ...riggered on high level Is Inactive Triggered on low level Thus if the user chooses Goes Active then as soon as the specified input changes from inactive to active the command will be triggered Also it...

Page 19: ...can choose from the following actions Will be activated Will be deactivated Will follow the input to change When the triggering condition is the Input Changes State you can then select change state as...

Page 20: ...2 Power on the Ursalink UC1114 Step 3 Run the Ursalink ToolBox and go to Upgrade Step 4 Click Browse and select the correct firmware file from the PC Step 5 Click Upgrade and the device will check if...

Page 21: ...ed to monitor an alarm sensor such as a manhole covers sensor or a water pressure sensor the Ursalink UC1114 will send out a message when any alarm occurs Configuration Hardware You should connect the...

Page 22: ...14 User Guide 22 Software 5 3 Control an Appliance 5 3 1 Control a Bulb by Sending a Message If you want to switch a 220 V light bulb on or off via a suitable LoRa message Configuration Hardware Softw...

Page 23: ...UC1114 User Guide 23 5 3 2 Send an Alert When Over temperature Occurs Software 5 3 3 Turn on the Heater Regularly Configuration Hardware...

Page 24: ...UC1114 User Guide 24 Software End...

Reviews: