E N G L I S H
25
12. A.
Selects amperes measurement mode.
13. MIN-MAX.
Selects RECORD mode and displays
recorded MAX, MIN, and AVG.
14. SOFT CREST.
Selects SOFT for a running 3-second
average, or CREST for half cycle peak
amperes.
15. AC DC.
Selects AC or DC mode.
16. LEVER.
Opens and closes clamp jaws.
17. RECORD.
Displayed (blinking) when MAX, MIN,
and AVG values are being recorded.
Duration of RECORD is limited by the
battery life.
18. MAX MIN AVG.
Displayed in RECORD mode by
pressing MIN-MAX pushbuttons.
19.
.
Displayed when HOLD pushbutton
has been pressed.
20. .
Displayed when pushbutton has been
pressed.
21. SOFT.
Displayed when current flow readings
or Hz or V readings are softened out
over 3-second intervals.
22. KΩVHz.
Displayed when measuring resistance,
voltage or frequency.
23. PEAK.
Displayed when current flow readings
are in halfcycle peak amperes (Crest
mode).
24. RMS.
Displayed when current reading is in
amperes rms.
25. OFF-SCALE ARROW.
Displayed when bar graph pointer is
off scale.
26. DUAL.
Displayed when measuring frequency
in digital and amperes in bar graph
simultaneously.
27. A.
Displayed when meter is measuring
amperes.
28. DIGITAL DISPLAY.
Displays 3999 counts, with two
decimal points relative to the two
ranges. But, displays 9999 counts in
frequency mode. Display is updated 4
times each second.
29. POINTERS.
Displayed to indicate position on bar
graph scale. Positions are updated 20
times per second.
30. ANALOG DISPLAY POLARITY.
Di or - when the pointers are