Urrea GGI810 User Manual And Warranty Download Page 21

19

E N G L I S H •

User's Manual

opened and closed by manually pressing the 
shutter lever. Move the lever to the CLOSED po-
sition to enrich the mixture for cold start.

PRIMER

CLOSED

OPEN

OUTPUT INDICATOR LIGHT

The output indicator light (green) illuminates 

when the generator is operating normally. Indi-

cates that the generator is producing electrical 

energy in the receptacles.

INDICATOR LIGHT OF OVERLOAD

If the generator is overloaded (more than 2000 

VA), or if a short circuit occurs in a connected 

device, the overload indicator light (red) will 

continue. The overload indicator light (red) will 

remain on, and after about four seconds, the 

power to the connected device (s) will turn off, 

and the output indicator light (green) will turn 

off.

OIL ALERT SYSTEM

The oil alert system is designed to prevent en-

gine damage caused by an insufficient amount 

of oil in the crankcase. Before the oil level in the 

crankcase can fall below a safety limit, the oil 

alert indicator light turn on and the oil warning 

system it automatically shuts off the engine (the 

engine switch remains in the ON position).

If the engine stops or the oil alert indicator light 

comes on when you pull the starter handle, 

check the engine oil level before troubleshoot-

ing in other areas.

OUTPUT INDICATOR L GHT
(GREEN)

OIL ALERT INDICATOR
LIGHT (RED)

OVERLOAD INDICATOR LIGTH
(RED)

LAND TERMINAL

The ground terminal of the generator is con-

nected to the generator frame, the non-current-

carrying metal parts of the generator, and the 

ground terminals of each receptacle.

Before using the ground terminal, consult a 

qualified electrician, an electrical inspector or 

the local authority competent for the codes or 

local ordinances that apply to the intended use 

of the generator.

ECONOMIC MODE

The economic system automatically reduces 

engine speed when all loads are off or discon-

nected. When the devices are switched on or 

reconnected, the motor returns to the proper 

speed to feed the electric charge.

If high electrical loads are connected simultane-

ously, turn the Eco-accelerator switch to the off 

position to reduce the voltage changes.

When the DC output is used, set the Eco-acceler-

ator switch to the OFF position.

ON: Recommended to minimize fuel consump-

tion and further reduce noise levels when no 

load is applied to the generator.

OFF: The Eco-accelerator system does not work.

AC CIRCUIT PROTECTOR

The AC circuit protector will automatically shut 

off if there is a short circuit or significant gen-

erator overload in the AC receptacles. If the 

circuit protector is automatically deactivated, 

check that the device is working properly and 

does not exceed the rated load capacity of the 

circuit before reset the circuit protector.

DC RECEPTACLE

The DC receptacle should ONLY be used to 

charge 12 volt automotive type batteries. The 

DC load output is not regulated.

DC CIRCUIT PROTECTOR

The DC circuit protector automatically turns off 

the charging circuit of the DC battery when the 

DC charging circuit is overloaded, when there is 

a problem with the battery, or when the con-

nections between the battery and the generator 

are improper.

CONNECTIONS TO AN ELECTRICAL SYSTEM

WARNING: Incorrect connections to a fixed elec-

trical system can allow electrical current from 

the generator to be returned by utility lines.

This feedback can electrocut the utility workers 

or other people who come in contact with the 

lines during a power outage, and the genera-

tor can explode, burn or cause fires when the 

power is restored. Consult the electric company 

or a qualified electrician.

GROUND CONNECTION

Portable generators have a system ground that 

connects the components of the frame to the 

ground terminals in the AC output receptacles. 

The system ground is not connected to the AC 

neutral wire. If the generator is tested by a re-

ceptacle tester, the same ground circuit condi-

tion will not be displayed as a receptacle for the 

home.

Summary of Contents for GGI810

Page 1: ...ad contenidas en este manual antes de operar esta herramienta WARNING Read understand and follow the safety rules in this manual before operating this tool Generador Inverter Inverter Generator GGI810...

Page 2: ......

Page 3: ...evisi n previa al uso Mantenimiento Gu a de soluci n de problemas Garant a Tarjeta de servicio 14 14 14 15 15 18 18 18 20 21 24 26 27 2 2 2 3 3 6 7 7 9 10 13 26 27 CONTENIDO CONTENT S MBOLOS SYMBOLS P...

Page 4: ...trico No abuse del cable No usar nunca el cable para llevar levantar o desenchufar la herramienta el ctrica Mantenga el cable lejos del calor acei te cantos vivos o piezas en movimiento Los cables da...

Page 5: ...tes m viles no est n desa lineadas o trabadas que no haya piezas rotas u otras condiciones que puedan afectar la ope raci n de las herramientas el ctricas Las herra mientas el ctricas se reparan antes...

Page 6: ...os generadores est n dise ados para ofrecer un servicio seguro y fiable si se opera de acuerdo a las instrucciones Leer y comprender el manual del propietario antes de operar el generador Usted puede...

Page 7: ...uinas fotocopiadoras Equipo tele f nico lamiento se ha instalado por un electricista calificado Utilice s lo un kit de funcionamiento en paralelo aprobado equipo opcional para conectar dos generadores...

Page 8: ...ongelador 300 500 Plancha para alimentos 330 1100 Plancha de ropa 500 1500 Foco 9 100 Radio 50 200 Refrigerador 190 2000 Sart n el ctrico 1200 Calefacci n port til 600 4800 Televisor 200 500 Tostadora...

Page 9: ...ble La palanca de ventilaci n debe estar en la posi ci n ON para que el motor funcione Cuando el motor no est en uso deje la palanca de ventilaci n en la posici n OFF para reducir la posibilidad de fu...

Page 10: ...e recept culo no se mostrar la misma condici n circuito de tierra como un recept culo para el hogar de salida verde se apagar SISTEMA DE ALERTA DE ACEITE El sistema de alerta de aceite est dise ado pa...

Page 11: ...ra dentro del rango indicado APLICACIONES AC Antes de conectar un aparato o del cable de ali mentaci n al generador Aseg rese de que est en buen estado de funcionamiento Aparatos defectuosos o cables...

Page 12: ...st n desconectados de los recept culos de AC Gire la palanca de ventilaci n de la tapa de combustible a la posici n ON 4 Para hacer arrancar un motor fr o mueva la palanca a la posici n CERRADO Para a...

Page 13: ...e est n certificados MANTENIMIENTO SEGURO Algunas de las precauciones de seguridad m s importantes Sin embargo no podemos avisarle sobre todos los peligros concebibles que pueden surgir al realizar el...

Page 14: ...est n desgastados o si el aislador est agrietado astillado o sucio 6 Mida la distancia entre electrodos de la buj a con un calibre de espesores del tipo de alambre Corrija el distancia si es nece sari...

Page 15: ...e La unidad tirita durante la operaci n La posici n de la palanca obturadora est incorrecta Mueva la palanca obturadora a la posici n abierto durante el uso La unidad libera humo blanco La temperatura...

Page 16: ...ation is unavoid able use a power supply protected by a Residual Current Device RCD The use of an RCD reduces the risk of electric shock PERSONAL SAFETY Stay alert watch what you are doing and use com...

Page 17: ...air personnel Service or main tenance performed by unqualified personnel could result in a risk of injury SPECIFIC SAFETY RULES DANGER Failure to follow these instructions and warnings may result in d...

Page 18: ...are wet could result in electric shock Keep the generator dry If the generator is stored outdoors with out protection against the weather check all electrical components in the panel of control befor...

Page 19: ...d state equipment such as a television set is used A power line conditioner is recommended for some solid state applications VOLTAGE REQUIREMENTS A power line conditioner should be used when running o...

Page 20: ...gnition switch in the following way OFF To turn off the engine ON To start the engine MOTOR SWITCH HANDLE ON To start the engine pull the starter handle until resistance is felt and then pull hard in...

Page 21: ...hen the devices are switched on or reconnected the motor returns to the proper speed to feed the electric charge If high electrical loads are connected simultane ously turn the Eco accelerator switch...

Page 22: ...ng cable to the DC receptacle of the generator 3 Connect the red cable from the battery charging cable to the positive terminal of the battery and the black cable to the negative terminal of the batte...

Page 23: ...he operation equipment in parallel after stopping the motors if you do not wish to resume parallel operation MAINTENANCE Good maintenance is essential for safe econom ical operation and problems It wi...

Page 24: ...e oil and squeeze out the excess oil The engine will produce smoke during ini tial startup if too much oil remains in the air filters 5 Reinstall the air filters 6 Make sure that the rubber gasket is...

Page 25: ...0 hours Clean the spark arrestor as follows Remove the four 6mm screws and remove the muffler protector Remove the three 6mm bolts and remove the muffler spark arrestor and muffler gasket Use a brush...

Page 26: ...it shudders during operation The choke lever position is incorrect Move the choke lever to the open position during operation The unit emits white smoke The temperature of the engine is too high maybe...

Page 27: ...DI GRAMA EL CTRICO WIRING DIAGRAM...

Page 28: ...plied with IMPORTANT The components of natural wear as air filters spark plug carbon brush recoil and maintenance service are not including as a warranty Check the maintenance prices in your local Ser...

Page 29: ...vel de aceite SAE30 o 10W 30 Check the oil level SAE30 o 10W 30 Limpieza general no usar solventes General clean up do not use solvents Limpiar el filtro de aire con aire comprimido Clean the Air Filt...

Page 30: ...ientas Profesionales S A de C V garantiza este producto por el termino de 1 a o en reparaci n componentes y mano de obra contra cualquier defecto de fabricaci n en motor y cabezal a partir de la fecha...