Urrea GGI810 User Manual And Warranty Download Page 16

14

GENERAL SAFETY RULES

Your GASOLINE GENERATOR has many features 
that will make your job faster and easier. Safety, 
performance and reliability have been given top 
priority in the design of this tool, qualities to 
make easy to maintain and to operate.

 WARNING: Read and understand all instruc-

tions. Failure to follow all indications listed be-
low, may result in electric shock, fire and/or seri-
ous personal injury.
SAVE THESE INSTRUCTIONS.

SAFETY IN WORKING AREA
Keep your work area clean and well lit. Clut-
tered benches and dark areas may cause acci-
dents. 
Do not operate power tools in explosive atmo-
spheres, such as in the presence of flammable 
liquids, gases or dust. Some power tools create 
sparks which may provoke fire. 
Keep away observers, children and visitors while 
operating a power tool. Distractions can cause 
you to lose control.

ELECTRIC SAFETY

Double insulation eliminates the need for the 
three wire grounded power cord and grounded 
power supply system. 
Avoid the body contact with grounded surfaces 
such as pipes, radiators and refrigerators. There 
is an increased risk of electric shock if your body 
is grounded. 
Don’t expose power tools to rain or wet condi-
tions. The presence of water into power tools 
will increase the risk of electric shock. 
Do not abuse of the power cord. Never use the 
power cord to carry the tool and do not pull 
the plug off the outlet. Keep the cable away of 
heat, oil, sharp edges or moving parts. Replace 
damaged cords immediately. Damaged cords in-
crease the risk of electric shock. 
When operating a power tool outside, use an 
outdoor extension cord marked “W-A” or “W”. 
These cords are rated for outdoor use and re-
duce the risk of electric shock.
If the use of a tool in a damp location is unavoid-
able, use a power supply protected by a Residual 
Current Device (RCD). The use of an RCD reduces 
the risk of electric shock.

PERSONAL SAFETY

Stay alert, watch what you are doing and use 
common sense when operating a power tool.
 
Don’t use the tool if you are tired or under the 
influence of drugs, alcohol or medication. A 
moment of inattention while operating power 
tools may cause a serious personal injury.

Dress properly. Do not wear loose clothing or 
jewelry.
 Contain long hair. Keep your hair, cloth-
ing and gloves away of moving parts. Loose 
clothes, jewelry or long hair can be caught in 
moving parts.

Avoid an accidental starting. Be sure that the 
switch is OFF before plugging in.
 Carrying tools 
with the finger on the switch or plug in the tool 
switch in ON may cause accidents.

Remove the adjusting keys or wrenches before 
turning the tool on. 
A wrench or a key that is 
left close to a rotating part of the tool may pro-
voke a personal injury.

Do not overreach. Keep proper footing and bal-
ance at all times. 
Proper footing and balance 
enables better control of the tools on unexpect-
ed situations.

Use safety equipment. Always wear eye protec-
tion.
 Dust mask, nonskid safety shoes, hard hat, 
or hearing protection must be used for appro-
priate conditions.

Before connecting the tool to a power source 
(receptacle, outlet, etc.) be sure that the voltage 
supplied is the same as that one specified on 
the nameplate of the tool.
 To use a not specified 
voltage may cause a serious injury to the user as 
well as damage the tool.

 IMPORTANT: This appliance is not intended 

for use by persons (including children) with re-
duced physical, sensory or mental capabilities 
may be different or reduced, or lack of experi-
ence or knowledge, unless such persons are su-
pervised or trained to operate the product by 
a person responsible for their safety. Children 
should be supervised to ensure they do not use 
the devices as toys.

Summary of Contents for GGI810

Page 1: ...ad contenidas en este manual antes de operar esta herramienta WARNING Read understand and follow the safety rules in this manual before operating this tool Generador Inverter Inverter Generator GGI810...

Page 2: ......

Page 3: ...evisi n previa al uso Mantenimiento Gu a de soluci n de problemas Garant a Tarjeta de servicio 14 14 14 15 15 18 18 18 20 21 24 26 27 2 2 2 3 3 6 7 7 9 10 13 26 27 CONTENIDO CONTENT S MBOLOS SYMBOLS P...

Page 4: ...trico No abuse del cable No usar nunca el cable para llevar levantar o desenchufar la herramienta el ctrica Mantenga el cable lejos del calor acei te cantos vivos o piezas en movimiento Los cables da...

Page 5: ...tes m viles no est n desa lineadas o trabadas que no haya piezas rotas u otras condiciones que puedan afectar la ope raci n de las herramientas el ctricas Las herra mientas el ctricas se reparan antes...

Page 6: ...os generadores est n dise ados para ofrecer un servicio seguro y fiable si se opera de acuerdo a las instrucciones Leer y comprender el manual del propietario antes de operar el generador Usted puede...

Page 7: ...uinas fotocopiadoras Equipo tele f nico lamiento se ha instalado por un electricista calificado Utilice s lo un kit de funcionamiento en paralelo aprobado equipo opcional para conectar dos generadores...

Page 8: ...ongelador 300 500 Plancha para alimentos 330 1100 Plancha de ropa 500 1500 Foco 9 100 Radio 50 200 Refrigerador 190 2000 Sart n el ctrico 1200 Calefacci n port til 600 4800 Televisor 200 500 Tostadora...

Page 9: ...ble La palanca de ventilaci n debe estar en la posi ci n ON para que el motor funcione Cuando el motor no est en uso deje la palanca de ventilaci n en la posici n OFF para reducir la posibilidad de fu...

Page 10: ...e recept culo no se mostrar la misma condici n circuito de tierra como un recept culo para el hogar de salida verde se apagar SISTEMA DE ALERTA DE ACEITE El sistema de alerta de aceite est dise ado pa...

Page 11: ...ra dentro del rango indicado APLICACIONES AC Antes de conectar un aparato o del cable de ali mentaci n al generador Aseg rese de que est en buen estado de funcionamiento Aparatos defectuosos o cables...

Page 12: ...st n desconectados de los recept culos de AC Gire la palanca de ventilaci n de la tapa de combustible a la posici n ON 4 Para hacer arrancar un motor fr o mueva la palanca a la posici n CERRADO Para a...

Page 13: ...e est n certificados MANTENIMIENTO SEGURO Algunas de las precauciones de seguridad m s importantes Sin embargo no podemos avisarle sobre todos los peligros concebibles que pueden surgir al realizar el...

Page 14: ...est n desgastados o si el aislador est agrietado astillado o sucio 6 Mida la distancia entre electrodos de la buj a con un calibre de espesores del tipo de alambre Corrija el distancia si es nece sari...

Page 15: ...e La unidad tirita durante la operaci n La posici n de la palanca obturadora est incorrecta Mueva la palanca obturadora a la posici n abierto durante el uso La unidad libera humo blanco La temperatura...

Page 16: ...ation is unavoid able use a power supply protected by a Residual Current Device RCD The use of an RCD reduces the risk of electric shock PERSONAL SAFETY Stay alert watch what you are doing and use com...

Page 17: ...air personnel Service or main tenance performed by unqualified personnel could result in a risk of injury SPECIFIC SAFETY RULES DANGER Failure to follow these instructions and warnings may result in d...

Page 18: ...are wet could result in electric shock Keep the generator dry If the generator is stored outdoors with out protection against the weather check all electrical components in the panel of control befor...

Page 19: ...d state equipment such as a television set is used A power line conditioner is recommended for some solid state applications VOLTAGE REQUIREMENTS A power line conditioner should be used when running o...

Page 20: ...gnition switch in the following way OFF To turn off the engine ON To start the engine MOTOR SWITCH HANDLE ON To start the engine pull the starter handle until resistance is felt and then pull hard in...

Page 21: ...hen the devices are switched on or reconnected the motor returns to the proper speed to feed the electric charge If high electrical loads are connected simultane ously turn the Eco accelerator switch...

Page 22: ...ng cable to the DC receptacle of the generator 3 Connect the red cable from the battery charging cable to the positive terminal of the battery and the black cable to the negative terminal of the batte...

Page 23: ...he operation equipment in parallel after stopping the motors if you do not wish to resume parallel operation MAINTENANCE Good maintenance is essential for safe econom ical operation and problems It wi...

Page 24: ...e oil and squeeze out the excess oil The engine will produce smoke during ini tial startup if too much oil remains in the air filters 5 Reinstall the air filters 6 Make sure that the rubber gasket is...

Page 25: ...0 hours Clean the spark arrestor as follows Remove the four 6mm screws and remove the muffler protector Remove the three 6mm bolts and remove the muffler spark arrestor and muffler gasket Use a brush...

Page 26: ...it shudders during operation The choke lever position is incorrect Move the choke lever to the open position during operation The unit emits white smoke The temperature of the engine is too high maybe...

Page 27: ...DI GRAMA EL CTRICO WIRING DIAGRAM...

Page 28: ...plied with IMPORTANT The components of natural wear as air filters spark plug carbon brush recoil and maintenance service are not including as a warranty Check the maintenance prices in your local Ser...

Page 29: ...vel de aceite SAE30 o 10W 30 Check the oil level SAE30 o 10W 30 Limpieza general no usar solventes General clean up do not use solvents Limpiar el filtro de aire con aire comprimido Clean the Air Filt...

Page 30: ...ientas Profesionales S A de C V garantiza este producto por el termino de 1 a o en reparaci n componentes y mano de obra contra cualquier defecto de fabricaci n en motor y cabezal a partir de la fecha...