background image

concerns this product.
NFPA 70 – National Electrical Code.
NFPA 37 – Standard for Installation and Use of 
Stationary Combustible Engines.
Agricultural Wiring handbook of Farm Standby 
Electric Power.

UNPACKING
When unpacking check to make sure that all 
parts are included.  If any parts are missing or 
broken, please call our distributor.

OPERATION

BEFORE OPERATION

GROUNDING THE GENERATOR
The  National  Electric  Code  requires  that  this 
product be properly connected to appropriate 
earth ground to help prevent electric shock. 
A ground terminal connected to the frame of 
the generator has been provided for this pur-
pose. 
Connect  a  length  of  a  heavy  gauge  (12  AWG 
min.) bare cooper cable between the ground 
lug attached to the generator´s frame (identi-
fied with a label with the ground symbol- see 
figure below) and a cooper rod drawn 1 meter 
into the ground which should provide a suit-
able ground connection. 
However, consult with a local electrician to in-
sure that local codes are being adhered to.

 WARNING: do not use a pipe carrying com-

bustible material as the ground source.

LUBRICATION
DO NOT attempt to start the engine without 
filling the engine crankcase with the proper 
amount and type of oil. Use SAE 30 oil.
Your generator has been shipped from the fac-
tory without oil in the engine crankcase. Op-
erating the unit without oil can damage the 
engine and lose the warranty.
Fill the engine according to the engine manu-
al. In this engine the plastic plug of the engine 
crankcase is the oil fill and check plug.Fill with 
oil and check 
the level using 
the marks set-
tings in the dip-
stick.

LOW OIL SENSOR
The  engine  is  equipped  with  an  oil  sensor.  If 
the  oil  level  becomes  lower  than  required, 
the sensor will activate a warning device and 
stop the engine (see the accompanying engine 
manual for more information).
If the generator turns off and the oil level is 
within specifications, check that the genera-
tor is not placed at an angle that forces the oil 
level to change. 
Place the generator in an even area to correct 
this problem. If the engine doesn’t start, the 
oil level could not be enough to shut off the 
automatic “low oil” swith. Make sure the oil 
cap is in the correct level.

FUEL
Fill the tank with unleaded fuel, clean and 
new. You can use regular-grade fuel as long as 
it has a high octane value (at least 85 octane). 
Always use a fuel additive. 
A fuel additive will minimize the development 
of fuel gum deposits during storage. The fuel 
additive can be added to the fuel int the gas 
tank or put toguether to the fuel in a storage 
container. The fuel and engine smoke are flam-
mable and potentially explosive. Use a suitable 
procedure  to  store  and  handle  fuel.  Always 
have ABC fire extinguisher nearby.

  CAUTION:  Do  not  overfill  the  tank.  Keep 

maximum fuel level to ¼ inch below the top of 
the tank. This will allow for expansion during 
warm weather, and so, avoiding spillage.

ELECTRIC EXTENSIONS OR CORDS
•  All  generator  loads  will  be  connected  from 
the control panel with extensions or cords with 
3-prong grounded plug for connection to120 
volts outlet and 4-prong grounded plug for 
connection to 220 volts outlets. 
•  See  Table  3  for  select  the  minimum  cable 
gauge of extensions or cords in agreement 
with the necessities of the loads.
• When the load increases must be used a cable 
extension of greater size. Using extensions of 
inadequate size it is in where can result in se-
rious problems with the voltage, reducing the 
electric energy applied to the tools and causing 
damage on them.
•  As  far  as  smaller  is  the  number  of  the  wire 
gauge greater is the conduction capacity, an 

15

E N G L I S H •

User’s manual

GG884 manual.indd   15

26/06/15   16:15

Summary of Contents for GG884

Page 1: ...User s Manual and Warranty ATENCI N Lea entienda y siga las instrucciones de seguridad contenidas en este manual antes de operar esta herramienta WARNING Read understand and follow the safety rules in...

Page 2: ...eraci n Mantenimiento Solucionador de problemas Datos t cnicos Garant a 12 14 14 15 18 19 19 20 3 5 5 6 10 10 11 20 2 E N G L I S H E S P A O L CONTENIDO CONTENT SIMBOLOS SYMBOLS PELIGRO ADVERTENCIA P...

Page 3: ...spas Recept culos da ados Falla al encender Vibraci n excesiva Llamas o humo Compartimiento cerrado Lluvia o inclemencia del tiempo No permita que la unidad se moje cuando est funcionado Verifique per...

Page 4: ...e entonces multiplique volts x ampes watts 1kW 1 000 W Los electro dom sticos o las herramientas impulsadas por motores requieren m s potencia que lo especi ficado en su placa de datos para arrancar N...

Page 5: ...S DE SOPORTE 15 ESCAPE 16 TANQUE DE COMBUSTIBLE 17 MANGO RETR CTIL 18 LLANTAS A VISOR DIGITAL B INDICADOR DE VOLTAJE DE CA C INDICADOR DE FRECUENCIA D INDICADOR DE LA HORA E ALERTA DE FALTA DE LUBRICA...

Page 6: ...C digo Nacional El ctrico requiere que este producto se aterrize adecuadamente para pre venir un choque el ctrico Para este prop sito se proporciona una terminal de tierra conecta da al marco del gene...

Page 7: ...de revisarse que cada extensi n sea del calibre m nimo de cable requerido Si se utiliza una extensi n con salidas para m s de una herramienta sume los amperes de placa de datos de cada una de las herr...

Page 8: ...os antes de reabastecerlo de combustible 3 Trate de no derramar combustible al reabas tecer el tanque Si hubo alg n derrame limpie lo inmediatamente 4 No mezcle gasolina y aceite 5 Siga las instruccio...

Page 9: ...nformaci n de servicio al cliente Verifique el nivel de aceite Reemplace el combustible viejo Cambie la buj a de encendido Verifique los ductos de combustible Aseg rese que la v lvula de combustible e...

Page 10: ...que siempre utilice un estabilizador para combustible Un estabiliza dor de combustible minimizar la formaci n de dep sitos de goma de combustible duran te el almacenamiento El estabilizador de com bus...

Page 11: ...E MOTOR CILINDRAJE TIEMPO DE TRABAJO APROX A UN 75 CAPACIDAD DE TANQUE DE GASOLINA CAPACIDAD DE ACEITE TEMPERATURA M XIMA CLASE DE AISLAMIENTO Robin SUBARU 404 cc 9 5 h 26 6 L 1 L 40 C F GENERAL DIMEN...

Page 12: ...ected equipment Sparking Damaged receptacles Engine starting failure Excessive vibration Flame or smoke Enclosed compartment Rain or inclement weather Do not let the unit get wet when operating Check...

Page 13: ...the generator the heaviest load and then add other items one at a time CAUTION Operating voltage and fre quency requirements of all electronic equip ment should be checked prior plugging them into th...

Page 14: ...tility circuit Give the generator at least two feet of space from any nearby wall to dissipate heat To avoid back feeding into utility systems isolation of the residence electrical system is required...

Page 15: ...arning device and stop the engine see the accompanying engine manual for more information If the generator turns off and the oil level is within specifications check that the genera tor is not placed...

Page 16: ...WARNING If the Generator will be used to replace facility power in times of outages the facility power input must be isolated Refer to the Electric Generator Safety Precautions These connections must...

Page 17: ...s running Voltage is regulated via the engine speed ad justed al the factory for correct output Read justing will void warranty CAUTION When applying a load do not exceed the maximum wattage rating of...

Page 18: ...dea to drain the fuel from the carburetor and gas tank LONG TERM STORAGE When the generator set is not being operated or is being stored more than one month fol low these instructions Replenish engine...

Page 19: ...UTPUT POWER PHASES FREQUENCY RATED AC VOLTAGE 8 400 W 7 000 W Monof sico 60 Hz 1 x 220 V 4 x 120 V MOTOR TYPE OF MOTOR DISPLACEMENT APPROXIMATELY RUN TIME AT 75 LOAD GASOLINE TANK CAPACITY OIL CAPACIT...

Page 20: ...s Profesionales S A de C V garantiza este producto por el termino de 1 a o en sus piezas componentes y mano de obra con tra cualquier defecto de fabricaci n a partir de la fecha de entrega Fecha de ve...

Reviews: