background image

9

E N G L I S H •

User’s manual

motor makes almost no noise.

• Stainless steel filter built into the suction 

tube inlet prevents contaminants from get-
ting in & causing damage

• Built-in 2” bung adaptor fits directly onto 

metal drums of 55 gallon. Bung adapter can 
be adjusted by 0.6” to adjust to drums with 
varying heights. Includes an additional bung 
thread converter for converting 2” standard 
bung threads to 2.5” X 5 mm buttress for us-
ing pump with IBC’s

• Telescopic suction tube extends from 33-1/2” 

to 49” for use with 55 gallon drums or 275-
330 gallon IBC’s.

• Supplied complete with 6.6’ hose & manu-

al dispensing nozzle with 3/4” OD Stainless 
Steel Spout.

WETTED COMPONENTS
Viton, POM, Stainless Steel, PE, NBR, PP.
RECOMMENDED USE:
Diesel, Kerosene, Bio Diesel, DEF/ Adblue, Wa-
ter based media, Antifreeze, Detergents, Pesti-
cides Herbicides, Urea, Light oils with viscosity 
upto 100 cst.
DO NOT USE WITH:
Gasoline, Corrosive chemicals, Lacquer thin-
ners, any material that is not compatible with 
the pump construction.
FLOW RATE
18.4 LPM (4.86 GPM).
DUTY CYCLE:
15 minutes On /15 Minutes Off.

MOTOR SPECIFICATION:

MOTOR TYPE DC

Brush Motor (5 Pole)

TEMPERATURE

41° to 104°F

MAX. VISCOSITY
OF MEDIA

100 cst

Electric drum pump designed for pumping fu-
els, water based media, light oils, DEF & select 
chemicals from metal drums of 55 gallon or 
275-330 gallon IBC’s

 WARNING: Carefully read the manual be-

fore attempting to use this product. Be sure to 
pay attention to all warnings and safety pre-
cautions throughout this manual.

GENERAL SAFETY RULES

 WARNING: Read and understand all in-

structions. Failure to follow the instructions 
listed below may result in personal injury.

SAVE FOR FUTURE REFERENCE

WORK AREA
• Keep your work area clean and well lit. 

Cluttered  benches  and  dark  areas  invite                      
accidents.

PERSONAL SAFETY

• Pump should be operated by trained person-

nel only.

• Always wear Safety Goggles when using the 

pump.

• Always use Gloves when using the pump.
• Do not point the discharge end towards 

yourself or anyone as there is potential haz-
ard for injection into skin / eyes.

• Never allow any part of the body to come in  

contact with the operating fluid.

• Before operating the pump , check hose for  

signs of wear , leaks or loose connections. If  
hose is weak , worn or damaged, replace the  
hose immediately.

• Incase of an accident, immediately seek 

 

emergency medical attention. Do not try to  
treat the injury yourself.

• Use only genuine factory parts for repair.
• Do not smoke when using / near the pump.
• Do not use the pump near a source of spark / 

open flames etc.

FEATURES

• Compact & lightweight construction.
• Convenient ON/OFF Switch with LED indica-

tor.

• Built-in fuse for overload protection silenced 

INTRODUCTION

Summary of Contents for 2363E

Page 1: ...ual de Usuario y Garant a User s Manual and Warranty ATENCI N Lea entienda y siga las instrucciones de seguridad contenidas en este manual antes de operar esta herramienta WARNING Read understand and...

Page 2: ...talaci n Operaci n C mo reemplazar el fusible Despiece Problemas frecuentes Notas Garant a 9 9 9 10 10 11 12 13 14 15 16 3 3 3 4 4 5 6 7 8 15 16 CONTENIDO CONTENT S MBOLOS SYMBOLS PELIGRO ADVERTENCIA...

Page 3: ...ibles fluidos base agua acei tes ligeros DEF y qu micos seleccionados para tambos de metal de 205 litros o contenedores IBC s de 1000 a 1250 litros ADVERTENCIA Lea atentamente el manual antes de inten...

Page 4: ...m con conectores tipo caim n Adaptador de AC a DC Voltaje 12 V DC 100 240 V AC 50 60 Hz M xima descarga 18 4 Litros por minuto 18 9 Litros por minuto INSTRUCCIONES DE OPERACI N CONOZCA SU HERRAMIENTA...

Page 5: ...tes de 24 V DC para evitar da os o accidentes OPERACI N 1 Retire la pistola dispensadora de la bomba 2 Coloque la pistola dentro del contenedor re ceptor para realizar la transferencia del l qui do 3...

Page 6: ...lida COMO EXTENDER EL TUBO DE SUCCI N TELESC PICA 1 Gire la tuerca de uni n en sentido contrario a las manecillas del reloj y despu s retire el fil tro del extremo del tubo de succi n 2 Despu s extien...

Page 7: ...7 E S P A O L Manual de Usuario DESPIECE 10 3 53 1 53 2 10 2 10 1 10...

Page 8: ...a 2 37 Manguera de descarga 1 38 Mango de pistola dispensadora 1 39 Tapa de pistola 1 40 Resorte de pistola 1 41 Pist n 1 42 O ring Pist n L 1 43 O ring Pist n S 1 44 Gatillo 1 45 Boquilla de pistola...

Page 9: ...based media light oils DEF select chemicals from metal drums of 55 gallon or 275 330 gallon IBC s WARNING Carefully read the manual be fore attempting to use this product Be sure to pay attention to...

Page 10: ...verter 7 Flexible Corrugated Hose 8 Telescopic 9 Suction Tube 10 SS Strainer 11 Nozzle Holster 12 12 V DC Cable WARNING Remove the pump from its packaging and carefully examine it Do not discard the p...

Page 11: ...anti clockwise and then pull the strainer end of the suction tube away from the bung DC CONNECTION 1 Connect the plug provided with the DC bat tery cable to the socket present at the back of the pump...

Page 12: ...e outlet 2 After extending the suction tube rotate the joint nut clockwise to fix the suction tube in the extended position HOW TO REPLACE THE FUSE 1 Remove the Hose Barb from the Outlet 2 Unscrew all...

Page 13: ...13 E N G L I S H User s manual EXPLODED VIEW 10 3 53 1 53 2 10 2 10 1 10...

Page 14: ...34 Hose Adapter 1 35 Joint Nut 3 36 Hose Clamp 2 37 Discharge Hose 1 38 Handle 1 39 Nozzle Cap 1 40 Nozzle Spring 1 41 Nozzle Piston 1 42 O ring Piston L 1 43 O ring Piston S 1 44 Nozzle Lever 1 45 S...

Page 15: ...15 Notas Notes Manual de usuario User s manual...

Page 16: ...guientes casos a Cuando la herramienta se haya utilizado en condiciones distintas a las normales b Cuando el producto hubiera sido alterado de su composici n original o reparado por personas no autori...

Reviews: