DS1092-090
82
PARK ACTION
The PARK ACTION is the action which is automatically executed after an inactivity time (PARK TIME) of the
Dome.
Select PARK ACTION and press the right arrow button to access the following submenu:
Option
Value
Description
None
At the end of the action performed by the user, no new
action is automatically executed.
Preset
At the end of the action performed by the user, and
after a configured time (PARK TIME), the dome will move
on one of the 128 previously stored presets, selected
by the user before the action starts.
Vector Scan
At the end of the action performed by the user, and
after a configured time (PARK TIME), the dome will
start one of the 6 previously stored VectorScan,
selected by the user before the action starts.
Pattern
At the end of the action performed by the user, and
after a configured time (PARK TIME), the dome will
start one of the 3 previously stored Pattern, selected
by the user before the action starts.
PanScan
At the end of the action performed by the user, and
after a configured time (PARK TIME), the dome will
execute a horizontal scan between two positions, stored
before the action starts.
AutoScan
At the end of the action performed by the user, and
after a configured time (PARK TIME), the dome will
execute a 360°horizontal scan, before the action
starts.
Park Action
RepeatLast
At the end of the action performed by the user, the
dome will start again the action in progress before the
interruption, and also the time that must elapse before
the action starts (see below).
Number
Variable, according
to the value
selected on “Park
Action”
This option allows to define in detail which single
action has to be activated. The single action number
that can be selected changes according to the
previously selected action (from 1 to 165, except the
non programmable ones for the Presets; from 1 to 6 for
VectorScan; from 1 to 3 for Patterns; 1 for PanScan; 1
for AutoScan). The selection of the desired number is
possible by pressing the button OPEN and going to the
respective screen.
Park Time
Time in seconds
Time after which the automatic action (PARK ACTION) is
activated.
POWER ON ACTION
The POWER ON ACTION is the action automatically activated at Dome power-on.
Select POWER ON ACTION and press the right arrow button to access the following submenu:
Park Action
>1Action
_________
2 Number
_________
3 Park Time
_________
IRIS CLOSE to Exit
Power On Action
>1Action
_________
2 Number
_________
IRIS CLOSE to Exit