13
DS1083-048
DESCRIPTION OF TERMINALS
]
LINE Bus line in
SE+ Positive for pedestrian crossing electric lock
SE-
Negative for pedestrian crossing electric lock
A
[
V3 Control camera signal (*)
V5 Reference for control camera signal (*)
B
[
V3 Control camera signal / video switch (*)
V5 Reference for control camera signal / video switch (*)
]
ILA
Output of device for deaf people Ref. 1148/48 (*)
]
SE
Driveway electric lock activation
T+
Command for video switch (*)
T-
Reference for video switch (*)
CT
Reference for PA and SP
PA
Hall button
SP
Open door detector
]
ILL Power supply for name tags lighting
-
Local power supply negative
+
Local power supply positive
EXP Connector for expansion module Ref. 1083/17
IC Connector for module with voice messages and led Ref. 1148/47 (*)
(*) available only on Ref. 1083/78 and 1083/79
DOOR UNITS CONFIGURATION
=
=
ON
ON
AUX
ON
DIP
4
3
2
1
5
0
5
3
8
4
9 1
6
2
7
ON
DIP
4
3
2
1
5
0
5
3
8
4
9 1
6
2
7
DOOR
TIME
ID
CONV
TIME
Default settings
: default indoor station settings are:
PE type:
main
Secondary number:
0
Door opener:
free
Interruption:
Not assured
Camera lights:
on
Guaranteed conversation time rotary:
30 s (pos 3)
Door lock release rotary:
1 s (pos 0)
Door unit number:
0