8
DS1139-003
WITH FLUSH-MOUNTED CASING Ø 60 MM
Install
fl
ush-mounting box at the height indicated.
Remove the plastic base from the door phone unit and
fi
x the base to the wall as shown in the drawing here
below.
1,55 m
n° 1 2,9 x 13 mm
countersunk screw
Box Ø 60 mm
n° 1 screw and screw
anchor included
Connect.
Fix the door phone to its plastic base.
1
DISTANCES, SECTIONS CABLES AND TECH SPECS
Type of connection
Max distance
Min - max cross
section
Call to
fl
oor level
30 m
0,5 - 1 mm
2
Panic Alarm
30 m
0,5 - 1 mm
2
Call repeating
30 m
0,5 - 1 mm
2
Yokis devices
10 m
0,5 - 1 mm
2
LAN
100 m
CAT5e (#)
(#) To ensure longest-range door phone operation, the cable must be a class 5e device and the twisted
pairs’ cross section must be AWG24.
The maximum resistance of the individual wires must not exceed 10ohm/100m.
The cable must be up to the following standards:
- EIA/TIA 568-B.2 or EIA/TIA 568-C.2
- EN50288 3-1
- IEC 61156-5
The connection between the door phone and POE switch must be ensured by a single cable without any
extra patch cords.
POE input voltage: .........................................................................................................................
48-54 V
Max consumption @ 48 V: ....................................................................................................................
125 mA
Operating Temperature: ...................................................................................................................
-5 ÷ 45°C
Maximum current X1/GT or Y1/GT contacts: .........................................................................
50 mA - 12 Vdc