background image

9

DS1139-004

switchboard.

Green LED under button

 

 then lights up.

 

2.2. ANSWERING THE CALL

Pressing the

 

 

button, the green LED under the button will start blinking; a conversation with the caller is 

established at this point. By pressing again the button

 

 

, the communication is closed.

2.3.

 

DOOR OPENER DURING CALL

With the door phone in stand-by condition

(3)

 or during call reception

(3)

 (received from the calling station) or 

in audio mode (with the calling station), the pedestrian gate or the garage gate can be opened by pressing 

buttons

 

 or 

 

respectively.

(3)

 

According to how the door opener is programmed: free or secret.

2.4.  FLOOR CALL

If a 

fl

 oor call is received, the door phone will play the ring tone chosen by the user.

  The function is only available if a button was connected to the “FC” terminals.

2.5. CALLING THE SWITCHBOARD

The user can call the switchboard, if this function has been con

fi

 gured in IPerVoice server,

 

using one of the 

two programmable calling buttons ( 

 

and 

 

) present on the door phone.

To perform the call, follow this procedure:

 

with the door phone in “STAND-BY” condition brie

fl

 y press button

 

, and then press the calling button associated to the “Call to switchboard” function.

 

Communication will 

be established if the switchboard picks up before the timeout. Otherwise, the door phone will be turned off 

and will ring as normal when the switchboard calls back. After replying, the green LED under the button will 

start blinking; a conversation is established at this point.

2.6. INTERCOM CALL

 

The function is activated by programming a call button on the door phone in the IPerVoice server. Proceed 
as follows to make the call: press button

   

and then press the required call button ( 

 

or 

 

); then wait for the 

called apartment to reply. Upon the reply, the green LED under the button will start blinking; a conversation 

with the called party is established at this point.

2.7.  CALL TONE SELECTION

Five call tones are available for selection on apartment stations of the IPerVoice system, one for each calling 

source.

The tones can be programmed  by following the simple sequence below.

1.  enter programming mode by holding button 

 

pressed for longer than 5 seconds; the yellow LED will 

blink slowly to indicate that programming mode has been selected and the door phone will beep 3 

times;

2. press button 

 

again for the number of times corresponding to the number of the call source for which 

you want to change the call tone according to the following table:

Number of presses of the button 

   

Call source 

1

From main calling station

2

From secondary calling station

3

Floor call

4

Intercom call

5

From switchboard

Summary of Contents for Miro

Page 1: ...HAND FREE DOOR PHONE INTERPHONE MAINS LIBRES IP INTERFONO MANOS LIBRES IP SPRECHANLAGE MIT FREISPRECHSYSTEM IP IP HANDSFREE DEURTELEFOON Sch Ref 1139 3 LIBRETTO UTENTE USER HANDBOOK NOTICE UTILISATEUR MANUAL DEL USUARIO BENUTZERHANDBUCH GEBRUIKSHANDLEIDING ...

Page 2: ...C DOOR OPENER 10 3 USER DATA RESET 11 4 REBOOTING THE DEVICE 11 The Ref 1139 3 is an IP device dedicated exclusively to the IPerVoice system 1 DESCRIPTION OF COMPONENTS 1 6 10 11 9 8 7 2 3 4 5 1 Microphone 2 Button see button function table 3 Button see button function table 4 Button to connect to Yokis devices 5 Button to connect to Yokis devices 6 Multicolour indicator LED 7 Call and conversatio...

Page 3: ...f current conversation Call volume adjustment for door and floor level calls the possible volume adjustments are in this order LOW HIGH MUTE Special function 2 Special function 2 Special function 2 Call to switchboard or intercom 2 Call source selection from main calling station from secondary calling station to floor intercom from switchboard Garage door opener or special function 2 Garage door o...

Page 4: ... be established if the switchboard picks up before the timeout Otherwise the door phone will be turned off and will ring as normal when the switchboard calls back After replying the green LED under the button will start blinking a conversation is established at this point 2 6 INTERCOM CALL The function is activated by programming a call button on the door phone in the IPerVoice server Proceed as f...

Page 5: ...onger than 5 seconds in all cases after 10 minutes the device exits programming state and the changed parameters are saved two long beeps are heard 2 9 PANIC ALARM The Panic Alarm signal can only be activated if a button was connected to the PANIC terminals When the button is pressed the door phone emits the floor call even if the door phone was in mute mode IMPORTANT The following requirements ar...

Page 6: ...5 seconds hold buttons and pressed for longer than 5 seconds The device will generate 2 long beeps and reboot The user data reset operation is irreversible 4 REBOOTING THE DEVICE Rebooting is used to reboot the device The operation cannot be undone To reboot the door phone must be in stand by mode Hold the button pressed for at least 7 seconds ...

Page 7: ...BT 20347 Area tecnica servizio clienti 39 011 23 39 810 http www urmet com e mail info urmet com MADE IN CHINA URMET S p A 10154 TORINO ITALY VIA BOLOGNA 188 C Telef 39 011 24 00 000 RIC AUT Fax 39 011 24 00 300 323 ...

Page 8: ...HONE INTERPHONE MAINS LIBRES IP INTERFONO MANOS LIBRES IP SPRECHANLAGE MIT FREISPRECHSYSTEM IP IP HANDSFREE DEURTELEFOON Sch Ref 1139 3 LIBRETTO DI INSTALLAZIONE INSTALLATION HANDBOOK NOTICE D INSTALLATION MANUAL DE INSTALACIÓN INSTALLATIONSANLEITUNG INSTALLATIEHANDLEIDING ...

Page 9: ...pply DOORPHONE POE PORT 2 12 way connector for connecting the door phone to optional devices for obtaining the following functions panic alarm call repetition floor call Yokis device activation WIRE DESCRIPTION FOR SYSTEM CONNECTIONS Colour Name Description Yellow PANIC Panic alarm Green X1 Button Blue GT Button common and White Y1 Button Grey Not used Colour Name Description Grey Not used Brown S...

Page 10: ...e Blue 6 Green 7 White Brown 8 Brown Grey sheath Cut the cables so that they protrude from the guide by about 5 mm insert the guide in its plug and crimp with the specially provided tool Plug 8 1 5 mm 8 1 Make sure that the grey sheath stays inside the plug This type of connection will NOT guarantee double insulation INSTALLATION WITH FLUSH MOUNTED CASING MOD 503 Install flush mounting box at the ...

Page 11: ... 1 mm2 Panic Alarm 30 m 0 5 1 mm2 Call repeating 30 m 0 5 1 mm2 Yokis devices 10 m 0 5 1 mm2 LAN 100 m CAT5e To ensure longest range door phone operation the cable must be a class 5e device and the twisted pairs cross section must be AWG24 The maximum resistance of the individual wires must not exceed 10ohm 100m The cable must be up to the following standards EIA TIA 568 B 2 or EIA TIA 568 C 2 EN5...

Page 12: ...500ER O F N L BP ANTENNA GT X1 Y1 R1 R1 R1 R1 R1 R1 Roller Max 10 m After suitably programming the Yokis devices it will be possible to activate the centralised closing of the rollers with a button for example a second button for example will activate the turning off of the lights For more information on YOKIS products please visit www yokis com ...

Page 13: ...BT 20317 Area tecnica servizio clienti 39 011 23 39 810 http www urmet com e mail info urmet com MADE IN CHINA URMET S p A 10154 TORINO ITALY VIA BOLOGNA 188 C Telef 39 011 24 00 000 RIC AUT Fax 39 011 24 00 300 323 ...