12
DS1072-028
13
DS1072-028
Arrange dip switches
in this position
Connect the keypad and the adapter
to the door unit.
FULL PROGRAMMING
PROCEDURE
With 1032/65 keypad
and 1072/60 adapter
Program
SYSTEM TYPE
Program
STATION TYPE
Program
CODE FORMAT
Program
STATION NUMBER (ID)
Programming procedure
(to be repeated
for each door unit)
1 2
(
*
)
Set up door units
for programming
using external
keypad
and adapter
(to be repeated
for all door units).
The programming LED will light up
and two confirmation beeps
will be heard
Define whether
each calling station
is main or secondary
main
secondary
Define the code type
to be used for apartment
station calls
numeric
(0001
÷
9999)
with
prefix
(x001
÷
x999)
with
suffix
(000x
÷
999x)
Assign a different identification
number to each
calling station
(x=number)
Possible numbers are:
1
÷
12 for main stations
0
÷
9 for second stations
The device must be programmed
as 2
nd
edition only if all the devices
in the system are 2
nd
edition
devices
1
st
edition
2
nd
edition
M
1
↵
M
2
↵
I
0
↵
I
1
↵
F
1
↵
N
x
↵
F
2
↵
F
3
↵
Go to the apartments
in the booking sequence,
hold the door opener button pressed
and pick up the door phone handset
Press calling buttons
of the door phones to be programmed
and note the sequence down.
DO NOT PRESS the stair case
light button (P1 by default) if a button
has been reserved for this purpose
Wait for 30 seconds
The LED will start
blinking and a confirmation
tone will be heard
Program
apartment
stations
(to be repeated
on any door unit
and all apartment
stations)
Programming
procedure
(to be repeated
for each door unit)
Program
PICK-UP TIME
Program
MINIMUM CONVERSATION TIME
(busy time)
Program
LOCK OPERATION TIME
Program
CODE-BUTTON ASSOCIATION
The relay controlling
the door lock can be managed
in pulse mode (00)
or stabile mode (from 1 to 30 s).
pulse
(xy=seconds)
Each apartment station
must be combined to a code
and calling button
as follows:
xyzw
xyzw = user code
nm = button number
The minimum conversation time
during which the conversation
cannot be interrupted
by other users
10
sec
20
sec
30
sec
40
sec
The apartment station
will beep twice
and the LED will blink
to confirm programming
The pick-up time
is the maximum time
from start of a call for the user
to answer the door phone
10
sec
20
sec
30
sec
40
sec
G
1
↵
G
4
↵
G
3
↵
G
2
↵
O
1
↵
0
D
0
↵
n
P
C
m
↵
x
D
y
↵
O
4
↵
O
3
↵
O
2
↵
A confirmation beep
will be heard each time
the button is pressed
Diagram B
Programming procedure for systems
with more than 3 main calling stations or with main and secondary
calling stations
.
(*)
All data will be lost if the dip switches are moved also after ending the programming procedure.