Dip switch settings and distances for connection between Ref.1092/300 and Ref.1092/316
(PASSIVE - ACTIVE)
DIP SWITCH
SETTINGS
DISTANCE (m)
DIP SWITCH
SETTINGS
DISTANCE (m)
250
÷
350
870
÷
950
350
÷
450
950
÷
1050
450
÷
550
1050
÷
1150
550
÷
630
1150
÷
1235
630
÷
690
1235
÷
1315 *
690
÷
750
1315
÷
1385 *
750
÷
810
1385
÷
1460 *
810
÷
870
1460
÷
1530 *
Table 3: distances with 24 AWG UTP CAT5 cable
*
For distances close to or higher than 1200 metres, use of an Urmet Domus Ref.1092/302 active
transmitter (instead of Ref.1092/300 passive transmitter) is recommended.
Important note:
•
Table 3 shows the approximate dip switch settings according to distance. This parameter may vary
according to the quantity of wire used for system installation.
•
The distances may vary according to the wire quality also when the latter is made by the same
manufacturer as the devices.
•
The distances shown in the table refer to the use of colour cameras. Higher distances may be
obtained using black and white cameras.
•