background image

APARTMENT DOOR PHONE STATIONS

sec.5a 

−−−− 

5

DIGIVOICE - Technical Manual

After 3 seconds or when the call button is pressed, the switchboard 

station will be activated in the operating mode it was in the last time it 

was turned off.

If  the  switchboard  station  is  in  DAY  service,  LED 

  will  be  on. 

If  the  switchboard  station  is  in  NIGHT  service,  LED 

  will  be  off. 

In both cases, the display will show the following message when the 

switchboard station is not in use:

Where, 000 is the switchboard station code.

The switchboard station display features LED backlighting with a 15” 

timeout. Backlighting is activated when the handset is picked up, a key 

is pressed, or a call or alarm signal is received.

To  turn  off  the  switchboard  station,  hold  down  the 

SHIFT

  key 

while pressing the 

ON

OFF

 button.

Note

if  the  switchboard  station  has  never  been  configured,  the 

message  “CONFIGURATION  REQUIRED”  will  appear  on  the 

display instead of “SYSTEM OK”.

Case 2: Switchboard station with access password

The switchboard station is activated by pressing the

 

ON

OFF

 button. 

The display will show the following message for 3 seconds:

The number of the software release is shown at the top of the display.

Enter  the  access  password  programmed  by  the  installer,  which  will 

be  shown  as  a  sequence  of  asterisks  on  the  bottom  line  of  the 

display. Then press the call button 

. The switchboard station will be 

activated in the operating mode it was in the last time it was turned 

off. 

If the password is incorrect or if 1 minute has passed since the

 

ON

OFF

button was pressed, the switchboard station will be deactivated.

If  the  switchboard  station  is  in  DAY  service,  LED 

  will  be  on. 

If  the  switchboard  station  is  in  NIGHT  service,  LED 

  will  be  off. 

In both cases, the display will show the following message when the 

switchboard station is not in use:

Where, 000 is the switchboard station code.

The switchboard station display features LED backlighting with a 15” 

timeout. Backlighting is activated when the handset is picked up, a key 

is pressed, or a call or alarm signal is received.

To  turn  off  the  switchboard  station,  hold  down  the 

SHIFT

  key 

while pressing the 

ON

OFF

 button.

Note

if  the  switchboard  station  has  never  been  configured,  the 

message  “CONFIGURATION  REQUIRED”  will  appear  on  the 

display instead of “SYSTEM OK”.

DAY SERvICE

In this operating condition, the switchboard station can be programmed 

for  three  different  modes:  MODE  A,  MODE  B,  and  MODE  C.  All 

switchboard stations in the system must be programmed for the same 

mode (A, B or C).

Mode A - Call interception enabled

In  this  mode,  the  switchboard  station  provides  concierge  service, 

intercepting calls from main entrance panels to apartment stations.

Calls  belong  to  the  zones  for  which  the  switchboard  station  is 

configured will be intercepted, as well as all calls to code 0 (i.e., calls 

made simply by pressing the entrance module call button) and calls 

directed  to  the  code  programmed  in  the  switchboard  station.  Other 

calls  are  sent  directly  to  the  apartment  stations;  if  the  latter  belong 

to  the  zone  assigned  to  another  switchboard  station,  the  calls  may 

be intercepted by it. The switchboard station can call any apartment 

station. 

The switchboard station will normally receive calls from the apartment 

stations  only  if  they  belong  to  its  assigned  zone.  If  desired,  the 

switchboard attendant can take these calls. If the attendant does not 

answer  the  calls,  they  will  be  stored  in  memory.  The  switchboard 

station can also be configured so that calls originating from apartment 

stations are completely ignored. In this case, the switchboard station 

will neither ring nor store the calls in memory.

Mode B - Call interception NOT enabled

This  operating  mode  is  similar  to  that  described  above  for  NIGHT 

service.

The  switchboard  station  does  not  receive  calls  from  outside  the 

building,  but  can  call  the  apartment  stations  and  receive  calls  from 

them.

Mode C - Calls from main entrance panels disabled

In this operating mode, calls cannot be put through from any of the 

main entrance modules. The switchboard station intercepts calls from 

the main entrance panels in the same way as described for Mode A; 

in this case, however, the switchboard station does not ring and puts 

the main entrance panel in busy status to indicate that the operation 

cannot be carried out. Operation as regards calls to apartment stations 

is as described for Mode A.

APARTMENT STATION Option

This option can be selected during configuration in cases where the 

switchboard station operates in NIGHT service and in DAY A or DAY 

B service.

The switchboard station will operate as if it were an ordinary apartment 

station, using the code for which it was configured.

OPERATING INSTRUCTIONS

ACTIvATION AND DEACTIvATION

Case : Switchboard station without access password

The switchboard station is activated by pressing the

 

ON

OFF

 button. 

The display will show the following message for 3 seconds:

The number of the software release is shown at the top of the display.

GUARD DOOR SWITCHBOARD STATION Ref. 038/40

OPERATING INSTRUCTIONS

REL1.0

SYSTEM OK

---------

23/05/2000  08:10:54

0001

REL1.0

SYSTEM OK

---------

ENTER PASSWORD

23/05/2000  08:10:54

0001

GUARD DOOR SWITCHBOARD STATION

Ref. 

038/40

Summary of Contents for 1038/40

Page 1: ...eedback monitoring 11 SPECIAL FUNCTIONS 11 Date time adjustment 11 Keypad lock activation deactivation 11 Call rerouting 12 Other display messages 12 Using a printer 12 Management from PC using pcvoic...

Page 2: ...apted for tabletop or wall mounting see the section covering installation COMPONENTS 1 Switchboard station body 2 Graphic display 3 Multi function keypad 4 Ringer volume control 5 Handset 6 Handset cr...

Page 3: ...ode of the apartment station called by the switchboard station Zone f 1 character This zone shows a symbol indicating the type of voice connection This symbol may be when main entrance panel eee has c...

Page 4: ...rd station can call any apartment station The switchboard station will normally receive calls from the apartment stations only if they belong to its assigned zone If desired the switchboard attendant...

Page 5: ...e mode A B or C Mode A Call interception enabled In this mode the switchboard station provides concierge service intercepting calls from main entrance panels to apartment stations Calls belong to the...

Page 6: ...Case 2 System with several switchboard stations in parallel Where there are two or more switchboard stations operating in parallel i e when the same zone is assigned to all switchboard stations the s...

Page 7: ...o apartment stations To call an apartment station the switchboard attendant must pick up the handset dial the apartment station code using the numeric keys 37 and press the call button If incorrect co...

Page 8: ...rom apartment station 1634 If the handset is picked up within 10 seconds the device will be ready for communication between the switchboard station and the apartment station and the display will show...

Page 9: ...on hold and switch the voice line to the main entrance panel by pressing key put the main entrance panel on hold and switch the voice line to the apartment station by pressing key or reestablish direc...

Page 10: ...panel 2 by pressing key 1 2 The display will show DOOR LOCK RELEASE FUNCTIONS The switchboard station can release locks at any door associated with a main or secondary entrance panel at any time This...

Page 11: ...MESSAGES SELF ACTIVATION FUNCTION The switchboard station can activate the main entrance modules by means of the self activation function In other words the switchboard attendant can establish video a...

Page 12: ...with a date time stamp Configuration report This report is printed at the end of switchboard station configuration and indicates all settings established for the station Door lock release messages Pri...

Page 13: ...ist 39 and click on button 41 an OK button and a Cancel button will appear Click on the OK button to confirm removal or on the Cancel button to exit from the procedure without making changes Editing a...

Page 14: ...supplied together with the unit inserting them through holes 8 PC VERSION INSTALLATION The switchboard station can be controlled from a PC In this case the PC s keyboard and mouse are used instead of...

Page 15: ...ay STEP 0 LANGUAGE The following menu will appear on the switchboard station display The following languages can also be programmed Press the number key associated with the desired language STEP 1 SWI...

Page 16: ...istobeconfiguredtohandletwo simultaneous calls select 2 For this purpose however the switchboard station and the main entrance panels must be physically connected by two separate voice lines STEP 5 CO...

Page 17: ...hange the function associated with key F1 simply select the desired number using the appropriate number key as indicated below and press the call button Select 0 to specify that no function is assigne...

Page 18: ...DE TO THE FUNCTIONS KEY Proceed as for step 12A STEP 18 PROGRAMMING THE ACCESS PASSWORD The display will show To change the password simply enter up to six numbers as desired and press the call button...

Page 19: ...rtment stations Ability to receive calls from other apartment stations can be disabled Disabled status is indicated by a LED Up to 10 unanswered calls from apartment stations can be stored in memory A...

Page 20: ...s in sequence Activate the configuration cycle noting the following points After selecting each parameter press the CALL button 4 to confirm selection The system will check all entered data rejecting...

Page 21: ...it is necessary to open the door RECEIVING AND STORING CALLS FROM OTHER APARTMENT STATIONS The special doorphone can receive calls from other apartment stations in the system and store unanswered call...

Page 22: ...d deactivate the feature simply press the SHIFT and MUTE keys 5 10 When the feature is active LED 11 flashes green Obviously the feature can be activated together with the MUTE function or separately...

Page 23: ...nd CV TERMINAL BLOCK FOR ADDITIONAL DOOR PHONE CONNECTION M3 FB Voice terminal B FA Voice terminal A CA Ringer and service terminal 0V Ground terminal reference for CA SPECIFICATIONS Consumption in lo...

Page 24: ...y a second courtesy tone will be emitted after 10 seconds CALLS FROM LANDING VIDEO MODULE Doorphone with single port decoder is designed to control video module Ref 1732 1 with associated wall bracket...

Page 25: ...e The programming cycle ends when the last code is received and the LED will go off Programming conditions and the corresponding LED states are shown in the table below If it is not necessary to progr...

Page 26: ...lease key Conversation privacy and provision for door lock release protected by privacy feature No door phone programming required during installation Two buttons for switchboard calls and auxiliary s...

Page 27: ...aker for ringing tone Electret condenser microphone Door lock release key Conversation privacy and provision for door lock release protected by privacy feature No door phone programming required durin...

Page 28: ...nel activation upon making a call to switchboard with optional additional circuit Ref 1138 55 Dimensions W x H x P 90 x 220 x 42mm TERMINAL DESIGNATIONS 0V Logic power supply negative input CA Ringer...

Page 29: ...g cables through hole 11 5 Reassemble switchboard station and supply it with power Note the telephone interface or PABX connecting cables must be less than 3 meters long TERMINAL DESIGNATIONS The conn...

Page 30: ...30 sec 5a DIGIVOICE Technical Manual...

Reviews: