background image

APARTMENT DOOR PHONE STATIONS

26 

−−−− 

sec.5a

DIGIVOICE - Technical Manual

INSTALLATION

ATLANTICO  DOOR  PHONE  WITH  2  BUTTONS 

Ref. 38/3

Featuring Atlantico styling, this doorphone is designed specifically for 

the Digivoice system.

 

The features of the door phone are:

• 

Voice  calls  to  and  from  entrance  panels  and/or  the  guard  door 

switchboard station.

• 

Dedicated speaker for ringing tone.

• 

Electret condenser microphone.

• 

Door lock release key.

• 

Conversation privacy, and provision for door lock release protected 

by privacy feature.

• 

No door phone programming required during installation.

  Two buttons for switchboard calls and auxiliary services (T1-T2).

  Adjustable call volume.

DESCRIPTION OF TERMINALS

FB   Voice conductor terminal B

FA   Voice conductor terminal A

CA   Ringer terminal

0V   Power supply negative input

100 mm

64 mm

236 mm

T2

T1

MAX

Maximum calling volume

MIN

Minimum calling volume

MUTE

No calling tone

Red

1

2

3

ATLANTICO DOOR PHONE WITH 2 BUTTONS Ref. 38/3

DESCRIPTION OF TERMINALS - INSTALLATION

ATLANTICO DOOR PHONE WITH 2 BUTTONS

Ref

38/3

Summary of Contents for 1038/40

Page 1: ...eedback monitoring 11 SPECIAL FUNCTIONS 11 Date time adjustment 11 Keypad lock activation deactivation 11 Call rerouting 12 Other display messages 12 Using a printer 12 Management from PC using pcvoic...

Page 2: ...apted for tabletop or wall mounting see the section covering installation COMPONENTS 1 Switchboard station body 2 Graphic display 3 Multi function keypad 4 Ringer volume control 5 Handset 6 Handset cr...

Page 3: ...ode of the apartment station called by the switchboard station Zone f 1 character This zone shows a symbol indicating the type of voice connection This symbol may be when main entrance panel eee has c...

Page 4: ...rd station can call any apartment station The switchboard station will normally receive calls from the apartment stations only if they belong to its assigned zone If desired the switchboard attendant...

Page 5: ...e mode A B or C Mode A Call interception enabled In this mode the switchboard station provides concierge service intercepting calls from main entrance panels to apartment stations Calls belong to the...

Page 6: ...Case 2 System with several switchboard stations in parallel Where there are two or more switchboard stations operating in parallel i e when the same zone is assigned to all switchboard stations the s...

Page 7: ...o apartment stations To call an apartment station the switchboard attendant must pick up the handset dial the apartment station code using the numeric keys 37 and press the call button If incorrect co...

Page 8: ...rom apartment station 1634 If the handset is picked up within 10 seconds the device will be ready for communication between the switchboard station and the apartment station and the display will show...

Page 9: ...on hold and switch the voice line to the main entrance panel by pressing key put the main entrance panel on hold and switch the voice line to the apartment station by pressing key or reestablish direc...

Page 10: ...panel 2 by pressing key 1 2 The display will show DOOR LOCK RELEASE FUNCTIONS The switchboard station can release locks at any door associated with a main or secondary entrance panel at any time This...

Page 11: ...MESSAGES SELF ACTIVATION FUNCTION The switchboard station can activate the main entrance modules by means of the self activation function In other words the switchboard attendant can establish video a...

Page 12: ...with a date time stamp Configuration report This report is printed at the end of switchboard station configuration and indicates all settings established for the station Door lock release messages Pri...

Page 13: ...ist 39 and click on button 41 an OK button and a Cancel button will appear Click on the OK button to confirm removal or on the Cancel button to exit from the procedure without making changes Editing a...

Page 14: ...supplied together with the unit inserting them through holes 8 PC VERSION INSTALLATION The switchboard station can be controlled from a PC In this case the PC s keyboard and mouse are used instead of...

Page 15: ...ay STEP 0 LANGUAGE The following menu will appear on the switchboard station display The following languages can also be programmed Press the number key associated with the desired language STEP 1 SWI...

Page 16: ...istobeconfiguredtohandletwo simultaneous calls select 2 For this purpose however the switchboard station and the main entrance panels must be physically connected by two separate voice lines STEP 5 CO...

Page 17: ...hange the function associated with key F1 simply select the desired number using the appropriate number key as indicated below and press the call button Select 0 to specify that no function is assigne...

Page 18: ...DE TO THE FUNCTIONS KEY Proceed as for step 12A STEP 18 PROGRAMMING THE ACCESS PASSWORD The display will show To change the password simply enter up to six numbers as desired and press the call button...

Page 19: ...rtment stations Ability to receive calls from other apartment stations can be disabled Disabled status is indicated by a LED Up to 10 unanswered calls from apartment stations can be stored in memory A...

Page 20: ...s in sequence Activate the configuration cycle noting the following points After selecting each parameter press the CALL button 4 to confirm selection The system will check all entered data rejecting...

Page 21: ...it is necessary to open the door RECEIVING AND STORING CALLS FROM OTHER APARTMENT STATIONS The special doorphone can receive calls from other apartment stations in the system and store unanswered call...

Page 22: ...d deactivate the feature simply press the SHIFT and MUTE keys 5 10 When the feature is active LED 11 flashes green Obviously the feature can be activated together with the MUTE function or separately...

Page 23: ...nd CV TERMINAL BLOCK FOR ADDITIONAL DOOR PHONE CONNECTION M3 FB Voice terminal B FA Voice terminal A CA Ringer and service terminal 0V Ground terminal reference for CA SPECIFICATIONS Consumption in lo...

Page 24: ...y a second courtesy tone will be emitted after 10 seconds CALLS FROM LANDING VIDEO MODULE Doorphone with single port decoder is designed to control video module Ref 1732 1 with associated wall bracket...

Page 25: ...e The programming cycle ends when the last code is received and the LED will go off Programming conditions and the corresponding LED states are shown in the table below If it is not necessary to progr...

Page 26: ...lease key Conversation privacy and provision for door lock release protected by privacy feature No door phone programming required during installation Two buttons for switchboard calls and auxiliary s...

Page 27: ...aker for ringing tone Electret condenser microphone Door lock release key Conversation privacy and provision for door lock release protected by privacy feature No door phone programming required durin...

Page 28: ...nel activation upon making a call to switchboard with optional additional circuit Ref 1138 55 Dimensions W x H x P 90 x 220 x 42mm TERMINAL DESIGNATIONS 0V Logic power supply negative input CA Ringer...

Page 29: ...g cables through hole 11 5 Reassemble switchboard station and supply it with power Note the telephone interface or PABX connecting cables must be less than 3 meters long TERMINAL DESIGNATIONS The conn...

Page 30: ...30 sec 5a DIGIVOICE Technical Manual...

Reviews: