13
Total Control
TRF-ZW10
Owner’s Manual
4.
Associations:
Allow programmers to configure two or more Z-Wave
device to work in conjunction with each other such as an area that
requires three-way lighting.
5.
Settings:
Allows the programmer to configure device specific
parameters such as Delayed Off, Basic Set Value, and more. The
owner’s manual or supporting resources of the included Z-Wave device
may be required.
6.
Tools:
Displays options that allow the programmer to troubleshoot or
provide maintenance over a specified Z-Wave device:
•
Remove Failed Node:
If the node is unresponsive and cannot be
excluded, select this option to exclude the failed node from the
TRF-ZW10 Device List.
•
Replace Failed Node:
Select to exclude an unresponsive node
and replace it with another device.
•
Update Network:
Select to have the TRF-ZW10 rediscover
devices and update communication routes from the gateway to
the Z-Wave device.
•
Update Firmware:
Before selecting this button, assure that the
firmware update file has been retrieved from the manufacturer.
Click on this button to update the selected device’s firmware.
•
Find:
If supported by the device, this button makes a form of
physical identification (for example blinking lights) to assist in
locating the device.
4
5
6