LT-3200 Switch
8
About
Description
Config Button
LED
Effect
LED Color Duration
Press / Hold # Press / Sec
Clear Notifications
Clears the RGB Bar of any notifications.
Press
2x
N/A
N/A
N/A
Inclusion / Exclusion
3x Tap of Config Button (30s timeout)
Press
3x
Pulse
Blue
(Default)
See desc
Disable Internal Relay
Disables the internal relay.
Press
8x
Fast Blink
Red
3x Blink
Enable Internal Relay
Enables the internal relay.
Press
8x
Fast Blink
Green
3x Blink
Z-Wave Signal Test
Tests the signal strength of the switch.
Hold
5-10s
Solid
Green
N/A
Parameter
Configuration
Change the parameters from the switch.
Hold
10-15s
Solid
Yellow
N/A
Factory Reset
Factory reset the switch.
Hold
20s
Solid
Red
3x Blink
Config Button Command Features
Parameter
#
Change at the
Switch?
About
Description
Range
Default
Size
(Bytes)
1
Yes
Power On State
Default power state the switch will revert to after power loss. (0 - Return
to State | 1 - On | 2 - Off)
0,1,2
0
1
2
Yes
Invert Switch
Inverts the switch. (0 - Disabled | 1 - Enabled)
0,1
0
1
3
No
Auto Off Timer
Automatically turns the switch off after
X
amount of seconds.
0-32767s
0
1
4
No
Association
Behavior
Sets when the switch should send commands to an associated device. (01
- Local | 02 - 3-way | 03 - 3-way & Local | 04 - Z-Wave Hub | 05 - Z-Wave
Hub & Local | 06 - Z-Wave Hub & 3-way | 07 - Z-Wave Hub & Local & 3-
Way | 08 - Timer | 09 - Timer & Local | 10 - Timer & 3-Way | 11 - Timer &
3-Way & Local | 12 - Timer & Z-Wave Hub | 13 - Timer & Z-Wave Hub &
Local | 14 - Timer & Z-Wave Hub & 3 -Way | 15 - All)
01-15
15
1
5
Yes
LED Indicator Color
Sets the default color of the LED Bar.
0-255
160
2
6
Yes
LED Indicator
Intensity
Sets the intensity of the LED Bar. (0 - Off | 1 - Low | 5 - Med | 10 - High)
0-10
3
1
7
Yes
LED Indicator
Intensity (When Off)
Intensity of the LED Bar when the switch is off. (0 - Off | 1 - Low | 5 - Med
| 10 - High)
0-10
1
1
8
No
LED Indicator Effect
Allows the LED Bar to perform different effects as notifications.
Use URC
Tool
0
4
10
No
Active Power
Reports
Sends a report when power levels raise or drop below the assigned value.
(0 - Disabled | 10 - 10% of prev report | 100 - 100% of prev report)
0,
1-100%
10
1
11
No
Periodic Power &
Energy Reports
Period of time before a report can be sent after a report was already
generated.
0-32767s
3600
2
12
No
Energy Reports
Sends a report when energy levels raise or drop below the assigned
value. (0 - Disabled | 10 - 10% of prev report | 100 - 100% of prev report)
0,
1-100%
10
1
13
No
Load Type
Adjustment
Can be used for dumb switch setups. (0 - Detect Type | 1 - Manually
Set Type)
0,1
0
2
51
No
Instant On
There is a delay that allows for multi-tap scene control. (0 - No Delay |
1 - Delay)
0,1
1
1
Switch Parameters