background image

LT-3200 Switch

4

Wiring Instructions

Please

do not try installing this device if you are unsure of how electrical circuits operate

within your home.

Technology upgrades can be exciting, but they can also be dangerous when not installed correctly.

!

This device is intended for
installation in accordance with
the National Electric Code and
local regulations in the United
States, or the Canadian
Electrical Code and local
regulations in Canada.

To reduce the risk of
overheating and possible
damage to equipment,

DO

NOT

attempt to control a

receptacle, motor driven
device, a fluorescent light
fixture, or an appliance.

Risk of Fire
Risk of Electrical Shock
Risk of Burns

Risque d’incendie
Risque de choc électrique
Risque de brûlures

Please

DO NOT

use this

switch to control Medical or
Life Support equipment.

TURN OFF THE POWER

to the

circuit for the switch and
lighting fixture at the circuit
breaker prior to installation.
Wiring live connections can and
will result in injury while also
damaging the device.

The metal plates surrounding
the switch assembly are a
heat sink. Max load rating of
400W is applicable when
installed in a single gang-box
with all six (6) tabs still intact.

PLEASE NOTE: URC is unable to provide electrical and/or wiring advice outside of this document. If you are
unable or unsure, please contact an electrician.

!

!

!

!

!

!

!

!

!

!

!

!

This switch is designed for use only with permanently installed
fixtures. To install multiple switches, remove the tabs as needed.

Unlike the LT-3200 Switch, the heat sink tabs are not used and
have no effect on performance.

Ce gradateur est conçu pour être utilisé uniquement avec des
luminaires installés en permanence. Pour installer plusieurs
gradateurs, supprimez les onglets si nécessaire.

Contrairement au LT-3200 Switch, les languettes du dissipateur de
chaleur ne sont pas utilisées et n'ont aucun effet sur les
performances.

!

CAUTION - PLEASE READ!

OTHER WARNINGS

SHOCK HAZARD

MULTIPLE SWITCHES

MAX WATTAGE KEY

MEDICAL EQUIPMENT

APPLIANCES AND MOTORS

1

4

5

6

2

3

Cet appareil est destiné à être
installé conformément au National
Electric Code et aux
réglementations locales des États-
Unis, ou au Code canadien de
l'électricité et aux réglementations
locales au Canada.

COUPEZ L'ALIMENTATION

du

circuit pour le gradateur et le
luminaire du disjoncteur avant
l'installation. Le câblage des
connexions en direct peut entraîner
et entraînera des blessures tout en
endommageant l'appareil.

Les plaques métalliques entourant
l'ensemble gradateur sont un
dissipateur de chaleur. L'indice de
charge maximal de 400W est
applicable lorsqu'il est installé dans
une seule boîte de gang avec les six
(6) onglets encore intacts.

Pour réduire le risque de surchauffe
et d'endommagement possible de
l'équipement, N'essayez

PAS

de

contrôler un réceptacle, un dispositif
à moteur, un appareil d'éclairage
fluorescent ou un appareil.

S'il vous plaît

NE PAS

utiliser ce

gradateur pour contrôler
l'équipement médical ou de survie.

Summary of Contents for LT-3200

Page 1: ...urers All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network Specifications Power 120V AC 60Hz Signal Frequency 908 42 MHz Operating Temperature Range 32 104 F 0 40 C Maximum Load 600W Incandescent 300W LED 150 CFL Approval UL Listed FCC IC Z Wave Plus Certified CAN ICES 003 B MB 003 B For indoor use Specifications subject to c...

Page 2: ...which is looking for Z Wave devices within its radius Z Wave devices outside this radius will not be found and need to either be moved within the radius or use a repeating device to reach it The second example shows how a repeater can be used to reach a device outside of the initial radius Keep this in mind when building your own network and make sure to use the range estimator below ...

Page 3: ...rated Concrete Stone 30cm 11 8 20 Aluminum Coating 1mm 0 04 100 Ceiling 30cm 11 8 70 Furniture Non wood 30cm 11 8 40 60 Glass No Metal Coating 5cm 2 0 10 Inner Wall 30cm 11 8 40 Iron Reinforced Concrete 30cm 11 8 30 90 Metal Grid 1mm 0 04 90 Outer Wall 30cm 11 8 60 Plaster 10cm 3 9 10 Pumice 30cm 11 8 10 Red Brick 30cm 11 8 35 Stone 30cm 11 8 30 Wood 30cm 11 8 40 60 ...

Page 4: ...ly with permanently installed fixtures To install multiple switches remove the tabs as needed Unlike the LT 3200 Switch the heat sink tabs are not used and have no effect on performance Ce gradateur est conçu pour être utilisé uniquement avec des luminaires installés en permanence Pour installer plusieurs gradateurs supprimez les onglets si nécessaire Contrairement au LT 3200 Switch les languettes...

Page 5: ...l Single Pole Installation Single Switch 3 Way Installation Line Load in Separate Boxes The LT 3200 can be used in a 3 way 4 way lighting installation The Master Load Controller must be defined in URC software Secondary controllers must be defined in URC software Multi Way will not work without prior programming Traveler Wire is not needed for Multi Way configurations of two or more LT 3200s Load ...

Page 6: ...trigger a specific scene D Air Gap Switch This will cut the power to the load your switch is wired to LT 3200 Switch Including A Switch Below are the steps for including pairing a switch to a Gateway Plan Prep and Install Locate an area to install the switch that is within a recommend distance from the Gateway Walls ceilings and even furniture may degrade communication between devices Remember to ...

Page 7: ...o confirm the settings were saved SmartStart SmartStart enabled products can be added into a Z Wave network by scanning the Z Wave QR Code present on the product with a controller providing SmartStart inclusion No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity Security 2 DSK The DSK can be found on th...

Page 8: ...d device 01 Local 02 3 way 03 3 way Local 04 Z Wave Hub 05 Z Wave Hub Local 06 Z Wave Hub 3 way 07 Z Wave Hub Local 3 Way 08 Timer 09 Timer Local 10 Timer 3 Way 11 Timer 3 Way Local 12 Timer Z Wave Hub 13 Timer Z Wave Hub Local 14 Timer Z Wave Hub 3 Way 15 All 01 15 15 1 5 Yes LED Indicator Color Sets the default color of the LED Bar 0 255 160 2 6 Yes LED Indicator Intensity Sets the intensity of ...

Page 9: ...E_UPDATE_MD Factory Default You may factory reset the switch by holding down the Config Button for twenty 20 or more seconds The LED Bar will turn Red and blink three 3 times to confirm However we recommend using a certified Z Wave controller to remove the device from your network for factory resetting the switch Only use either of these procedures in the event that the network primary controller ...

Page 10: ... cause undesired operation This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation Thi...

Reviews: