background image

Urban Fires UF670RC & UF700RC Installation & Use Instructions V1.3 Sept Page  13  

14.0 User Instructions

14.01 If the burner system is exposed to weather directly from above (for example, in a firebowl, firepit or a 
firetable) INSTALLER you must advise the end user that a Weathercover to protect the burner and pilot is 
essential to the correct long term operation of the appliance. 

This component should be used whenever the 

fi re is not in use. Failure to do so will void the warranty.  

Urban Fires can provide a steel or fabric weathercover to order. 

To fit the optional weathercover ensure the fire is off and cooled. 

The fire MUST NOT be operated while the cover is fitted. 

The cover MUST NOT be fitted while the fire is hot. A cooling period of 20-30 minutes should be observed 
before replacing the weathercover.  

Objects such as wood, coal, charcoal, fire logs or any other solid fuels MUST NOT be burnt on the outdoor 
gas burner. Cigarettes or other materials should not be thrown into the fire. 

Under no circumstances should any part of your body enter the gas fi replace during start-up or whilst 

the fi re is running.

Summary of Contents for UF670RCS

Page 1: ...anty BATTERIES NOT SUPPLIED PP3 REQUIRED The appliance shall be installed in accordance with This installation instruction booklet Local gas installation regulations and The Rules in Force BS 5440 1 B...

Page 2: ...on Outside gas burners must be installed within a suitable non combustible outdoor fireplace such as a firepit firetable or firebowl for example the concrete firepit illustrated below To operate corre...

Page 3: ...the burner 10 10 0 Fixing the burner into the fireplace 11 11 0 Connecting the Switch Panel 12 12 0 Testing of the power switch ignition 12 13 0 Placement of ceramic fire media 11 12 14 0 User Instru...

Page 4: ...a remote handset The handset controls a series of electronic circuits to operate 1 the ignition sequence 2 up down control of flame height and 3 to turn OFF the appliance The Data Label containing al...

Page 5: ...Urban Fires UF670RC UF700RC Installation Use Instructions V1 3 Sept Page 5 1 2 Technical Data Please note that this appliance is for decorative purposes You cannot cook on this appliance...

Page 6: ...e batteries have been placed inside replace the cover and seal the IP rated Control Box assembly 2 2 Normal Power Source Supplied transformer To connect the UF670RC UF700RC to 240v mains electricity i...

Page 7: ...0 Wall cladding around fire 4 1 The temperature of a wall directly above the heater does get hot and hence may discolour certain exterior paint finishes 4 2 Some exhaust stains may also become visible...

Page 8: ...losed but any enclosure in which the appliance is used should comply with one of the following 6 1 An enclosure with walls on all sides but at least one permanent opening at ground level and no over h...

Page 9: ...eated in a corner the following drawings give the minimum sized interior wall dimensions possible 7 2 Allowances should be made for cladding the internal sides of the cavity 7 3 Dimensions of the cavi...

Page 10: ...gas supply tube is fitted with 8mm compression fitting termination supplied with this fire Connect the incoming gas supply directly to the 8mm fitting Check gas tightness 9 2 An accessible inline iso...

Page 11: ...e plates are supplied within the bubble wrap packaging or in a separate pacakge TIP Use the finger holes to easily remove the burner assembly from the masonry cutout or burner tray 13 2 Urban Fires Cr...

Page 12: ...firepit right having laid one layer of Crystalight seperate the large medium and small pebbles 13 7 Start by placing the larger pebbles around the burner taking care not to block the pilot light or i...

Page 13: ...so will void the warranty Urban Fires can provide a steel or fabric weathercover to order To fit the optional weathercover ensure the fire is off and cooled The fire MUST NOT be operated while the cov...

Page 14: ...e AAA batteries are used for the remote control handset The life of the batteries is about a year with normal use 14 2 Pairing the handset with the receiver Before using the appliance for the first ti...

Page 15: ...e has been started NB If the pilot light doesn t remain lit after 3 attempts you must turn off the gas tap and warn your installer A few seconds after starting the pilot the main burner will start to...

Page 16: ...pebbles can be dried out by normal use of the fireplace 15 3 Periodically the pilot and burner s should be checked visually for carbon soot build up and garden debris a consistent flame and clean bur...

Page 17: ...the handset can you hear the motorised gas valve re setting If not you can reset the ignition process electronic controls and motorised gas valve by turning off the 240V supply waiting 30 seconds swi...

Page 18: ...Urban Fires UF670RC UF700RC Installation Use Instructions V1 3 Sept 2019 Page 18 17 0 Burner Replacement Parts...

Page 19: ...Urban Fires UF670RC UF700RC Installation Use Instructions V1 3 Sept Page 19 18 0 Control Box replacement parts...

Page 20: ...mbar or Propane G31 my be set at a supply pressure of 37mbar and Butane G30 at 28 30mBar The conversion kit consists of one 1 main burner injector and one 1 complete pilot light assembly Fig 1 Invert...