STEP 11A
ROUTE GAS LINE. APPLY A THIN LAYER OF PIPE DOPE OR
THREAD SEALANT TO THE THREADED FITTINGS. CONNECT
THE GAS SUPPLY TO THE LANTERN AND HAND TIGHTEN ALL
FITTINGS. ENSURE THAT THE FITTINGS ARE NOT CROSS-
THREADED. CONTINUE TO TIGHTEN WITH THE APPROPRIATE
SIZED WRENCHES.
STEP 11B
CONNECT 120V HOUSE SUPPLY TO (120V) PRIMARY SIDE OF
TRANSFORMER
CONNECT BURNER ASSEMBLY WIRES TO (24V) SECONDARY
SIDE OF TRANSFORMER
STEP 12
SLIP THE BURNER COVER OVER THE BURNER ASSEMBLY.
STEP 13
OPEN THE GAS VALVE JUST ENOUGH TO IGNITE A FLAME AT
THE BURNER TIP.
STEP 14
ADJUST THE FLAME TO YOUR PREFERENCE BY ADJUSTING
THE LEVER POSITION OF THE MANUAL GAS VALVE. WE
RECOMMEND THAT THE FLAME BE NO LARGER THAN 2
INCHES IN HEIGHT.
STEP 15
IMPORTANT: IF THE FIXTURE IS INSTALLED IN AN EXTERIOR
LOCATION, RUN A BEAD OF SEALANT AROUND THE
PERIMETER OF THE BACKPLATE TO PREVENT WATER
FROM GETTING BEHIND THE BACKPLATE.