STEP 1

SHUT OFF THE MAIN ELECTRICAL SUPPLY TO THE JUNCTION 
BOX FROM THE FUSE BOX/CIRCUIT BREAKER.  TURNING POWER 
OFF AT THE SWITCH IS NOT SUFFICIENT.

STEP 2

REMOVE MOUNTING PLATE FROM THE BACK OF THE FIXTURE 
USING THE HEX WRENCH PROVIDED AND SET FIXTURE AND SET 
SCREWS ASIDE.

STEP 3

LOCATE JUNCTION BOX AND PULL HOUSE SUPPLY CIRCUIT 
WIRING THROUGH THE WIRE-WAY HOLE OF THE MOUNTING PLATE. 
ATTACH THE MOUNTING PLATE DIRECTLY TO THE JUNCTION BOX 
AND/OR DIRECTLY TO THE WALL SURFACE USING THE MOUNTING 
SCREWS AND EXPANSION ANCHORS PROVIDED.  IT IS IMPORTANT 
TO CHECK LEVEL ON THE MOUNTED WALL PLATE.

STEP 4

USING THE WIRE NUTS PROVIDED, MAKE ELECTRICAL CONNECTIONS 
BY FOLLOWING THE ELECTRICAL CONFIGURATION TABLE BELOW.  
ENSURE THAT ALL ELECTRICAL CONNECTIONS ARE WRAPPED WITH 
UL-LISTED ELECTRICAL TAPE.

STEP 5

ATTACH THE FIXTURE BACKPLATE TO THE MOUNTING PLATE BY 
SLIDING THE FIXTURE OVER THE TOP OF THE MOUNTING PLATE 
AND THEN SECURE THE FIXTURE AT THE BOTTOM WITH THE SET 
SCREWS PROVIDED.  BE CAREFUL TO AVOID SCRATCHING THE 
FINISH ON THE FIXTURE.

STEP 6

ATTACH THE FIXTURE BODY TO THE BACKPLATE OF THE FIXTURE 
BY SLIDING THE BODY OVER THE BACKPLATE AND SECURING AT 
THE TOP AND BOTTOM WITH THE MACHINE SCREWS PROVIDED.

STEP 7

ONCE THE FIXTURE IS SECURED TO THE WALL SURFACE, RUN 
A SMALL BEAD OF SEALANT AROUND THE PERIMETER OF THE 
BACKPLATE TO PREVENT WATER FROM REACHING THE WIRE 
CONNECTIONS.

STEP 8

INSTALL LIGHT BULB/S IN FIXTURE SOCKET AND RESTORE 
POWER TO THE CIRCUIT.  CONFIRM PROPER OPERATION OF THE 
LIGHT FIXTURE.

MOUNTING INSTRUCTIONS

MOUNTING DIAGRAM  

ELECTRICAL CONFIGURATION TABLE

FROM HOME

FROM LUMINAIRE

CONNECT BLACK OR RED (HOT)  

HOUSE SUPPLY CIRCUIT WIRE TO:

 LUMINAIRE ROUND WIRE (HOT)

CONNECT WHITE (NEUTRAL) 

HOUSE SUPPLY CIRCUIT WIRE TO:

LUMINAIRE RIBBED WIRE 

(NEUTRAL)

CONNECT GREEN INSULATED OR BARE COPPER (GROUND -) HOUSE 

SUPPLY CIRCUIT WIRE AND LUMINAIRE BARE STRANDED WIRE 

(GROUND -) TO GREEN GROUND SCREW ON CROSSBAR.

GENERAL NOTE:  USE UL LISTED WIRE NUTS FOR THE 
WIRING CONNECTIONS IN THIS LUMINAIRE.  WRAP WIRE NUT 
CONNECTIONS WITH UL LISTED ELECTRICAL TAPE.