Section 2 - Service and Repair
Sensors
107099-002 TM12 Work Platform
Page 2-23
2-10 S
ENSORS
T
I L T
S
E N S O R
W A R N I N G
!
!
Never perform service on the machine in the elevating assembly area while platform is elevated without first
blocking the elevating assembly.
DO NOT stand in elevating assembly area while deploying or storing brace.
The Tilt Sensor has three wires; red-power (24v in), black-ground, white-output (24v out). To verify the sen-
sor is working properly, there is one red LED under the sensor. If the LED is on, the sensor is off level.
Figure 2-18:
Tilt Sensor
A
DJUSTMENT
1. Place machine on a firm, level surface.
2. Use an inclinometer to ensure that the chas-
sis is level front to rear and side to side.
3. Adjust the three leveling screws until the bub-
ble is centered in the circle on the attached
bubble level.
T
EST
1. Raise the platform approximately 2 m (
7 ft.
).
2. Support the elevating assembly (see “Sup-
porting Elevating Assembly” on page 2-3).
3. Push the level sensor to the side.
The red LED should turn on, and the tilt alarm
should sound.
Adjusting Screws
(only one visible)
Bubble Level
Summary of Contents for TM12