Section 2 - Service and Repair
Preventative Maintenance
107099-002 TM12 Work Platform
Page 2-5
P
R E V E N T A T I V E
M
A I N T E N A N C E
C
H E C K
L
I S T
COMPONENT
INSPECTION OR SERVICES
INTERVAL
Y
N
R
Battery
System
Check electrolyte level
Daily
Check battery cable condition
Daily
Charge batteries
Daily
Check charger condition & operation
Daily
Check specific gravity
6m
Clean exterior
6m
Clean terminals
6m
Hydraulic Fluid*
Check fluid level
Daily
Change Filter
6m
Drain and replace fluid
2y
Hydraulic System
Check for leaks
Daily
Check hose connections
30d
Check hoses for exterior wear
30d
Drive Motors
Check for operation and leaks
Daily
Emergency Down Check procedure for Emergency Down
Daily
Hydraulic Pump
Check for fitting leaks
Daily
Wipe clean
30d
Check for leaks at mating surfaces
30d
Check mounting bolts for proper torque
6m
Controller
Check condition & operation
Daily
Platform Deck &
Rails
Check fasteners for proper torque
Daily
Check welds for cracks
Daily
Check condition of deck
Daily
Check entry way closure
Daily
Elevating
Assembly
Inspect for external damage, dents, loose
rivets or cracks
Daily
Check chains and sheaves for wear
6m
Lubricate lift chains
6m
Check chain tension
1yr
Remove and inspect chains
5yr
Chassis
Check cables for pinch or rubbing points
Daily
Check welds for cracks
Daily
Check component mounting for proper
torque
6m
Lift Cylinder
Check for leaks
Daily
Check for proper torque
6m
Entire Unit
Perform pre-operation inspection
Daily
Check for and repair collision damage
Daily
Lubricate
30d
Check fasteners for proper torque
6m
Check for corrosion; remove and repaint
6m
Labels
Check for peeling, missing, or unreadable
labels & replace
Daily
Wheels
Check for loose components
Daily
Steering System
Oil pivot pins
30d
Oil king pins
30d
Check steering cylinder for leaks
30d
Check hardware & fittings for proper torque
6m
COMPONENT
INSPECTION OR SERVICES
INTERVAL
Y
N
R
NOTE: Use ISO #46 during summer and ISO #32 during winter.
P
REVENTATIVE
M
AINTENANCE
K
EY
Interval
Daily=each shift or every day
50h/30d=every 50 hours or 30 days
250h/6m=every 250 hours or 6 months
500h/1y=every 500 hours or 1 year
1000h/2y=every 1000 hours or 2 years
Y=Yes/Acceptable
N=No/Not Acceptable
R=Repaired/Acceptable
P
REVENTATIVE
M
AINTENANCE
R
EPORT
Date: _______________________________________
Owner:______________________________________
Model No: ___________________________________
Serial No: ___________________________________
Serviced By: _________________________________
Service Interval: ______________________________
Summary of Contents for TM12
Page 1: ...TM12 Work Platform Serial Numbers 7352 Current Publication Number 107099 002 ...
Page 4: ...Foreword Page ii Service Manual NOTES ...
Page 19: ...Labels 107098 002 TM12 Operator Manual Page 15 Figure 11 Safety Labels Locations ...
Page 82: ...Section 4 Schematics Page 4 6 107099 002 TM12 Work Platform NOTES ...