2.2 Specifications

Basic Parameters 

UE-24Li2900WH

25.6

2840
2550

442*420*120

26.5

23.2 ~ 28.5
28.2 ~ 28.5

55
85

100A @ 15 sec

RS485 / CAN

20 pcs

0°C ~ 55°C Charge

-10°C ~ 55°C Discharge

-20°C ~ 45°C

IP20

5% ~ 95% RH

< 2000 m

IEC62619 / CE/ RoHS / UN38.3

10+ Years (25°C / 77°F)

Nominal Voltage (V)
Nominal Capacity (Wh)
Usable Capacity (Wh)
Dimension (mm)
Weight (Kg)
Discharge Voltage (V)
Charge Voltage (V)

Recommend Charge / Discharge Current (A)

Maximum Charge / Discharge Current (A)
Peak Charge / Discharge Current (A)
Communication

Configuration (Maximum in 1 Battery Group)

Working Temperature

Shelf Temperature
Ingress Protection
Humidity
Altitude

Certification

Design life

ecoline

www.masterbattery.es/en

UE-24Li2900WH

Summary of Contents for UE-24Li2900WH

Page 1: ...Rechargeable Lithium Ion Battery UE 24Li2900WH Product Manual ecoline Information Version 2 0 20UPSV0102 ...

Page 2: ...face Instruction 07 UE 24Li2900WH Product Front Interface 07 LED Indicators Instructions 07 Definition of RJ45 Port Pin 09 Definition of RJ11 Port Pin 09 3 Safe Handling of Lithium Batteries Guide 3 1 Schematic Diagram of Solution 11 3 2 Explanation of Symbol 11 3 3 Tools 12 3 4 Safety Gear 12 4 Installation 4 1 Package Items 13 Unpacking and check the Packing List 13 4 2 Installation Location 14 In...

Page 3: ...nd the SOC should be no less than 90 3 Battery needs to be recharged within 12 hours after fully discharged 4 Do not expose the battery module and cables in an outdoor environment 5 All the battery terminals must be disconnected for maintenance 6 Please contact the supplier within 24 hours if there is something abnormal 7 Do not use cleaning solvents to clean battery 8 Do not expose battery to flam...

Page 4: ...be less than 100mΩ 7 Please ensured the electrical parameters of battery system are compatible to related equipment 8 Keep the battery away from water and fire 1 2 In Using 1 If the battery system needs to be moved or repaired the power must be cut off and the battery is completely shut down 2 It is prohibited to connect the battery with different type of battery 3 It is prohibited to put the batte...

Page 5: ... and longer power supporting duration requirements 2 1 Features The whole module is non toxic non polluting and environmentally friendly Cathode material is made from LiFePO4 with safety performance and long cycle life Battery management system BMS has protection functions including over discharge over charge over current and high low temperature The system can automatically manage charge and disc...

Page 6: ...arge 20 C 45 C IP20 5 95 RH 2000 m IEC62619 CE RoHS UN38 3 10 Years 25 C 77 F Nominal Voltage V Nominal Capacity Wh Usable Capacity Wh Dimension mm Weight Kg Discharge Voltage V Charge Voltage V Recommend Charge Discharge Current A Maximum Charge Discharge Current A Peak Charge Discharge Current A Communication Configuration Maximum in 1 Battery Group Working Temperature Shelf Temperature Ingress P...

Page 7: ...e battery has alarm Combine with SOC LEDs to show which kind of alarm in detail Please check below table LED Indicators Instructions for the detailed definition Protection Protection light RED LED to show the battery is under BMS protection Combine with SOC LEDs to show which kind of protection in detail Please check below table LED Indicators Instructions for the detailed definition LED Status Indi...

Page 8: ... reason charging over current 1 2 Over Voltage Discharge MOS OFF Possible reason discharging over current 1 2 Low Voltage Short circuit Reverse connected Charge and discharge MOS all OFF Possible reason Over Low Temperature MOS Over Temperature i2c error Internal communication error Address assignment error Critical Failure MOSFAIL FUSE broken _ _ _ _ _ _ 100 76 75 51 50 26 25 0 _ _ _ _ Low SOC SO...

Page 9: ...e RS485 protocol for UE 24Li2900WH for communication between multiple parallel batteries and between master battery to host equipment CAN CAN Communication Terminal RJ45 port follow Upower Ecoline Low voltage protocol CAN for communication between master battery and host equipment Definition of RJ45 Port Pin Definition of RJ11 Port Pin RJ45 Plug RJ45 Port No RS485 Pin 1 2 3 4 5 6 7 8 CAN Pin RS485A ...

Page 10: ... single module each terminal can achieve charging and discharging function For power cables it must keep pressing this Lock Button during pulling out the power plug BMS function Protection and Alarm Charge Discharge Cut off Charge Over Voltage Discharge Under Voltage Charge Discharge Over Current High Low Temperature Short Circuit Management and Monitor Cells Balance Intelligent Charge Model Capac...

Page 11: ... Vieja 2 28052 Madrid España Tel 34 918 021 649 Fax 34 917 750 542 info masterbattery es 11 3 Safe Handling of Lithium Batteries Guide 3 1 Schematic Diagram of Solution 3 2 Explanation of Symbol ecoline www masterbattery es en UE 24Li2900WH ...

Page 12: ...he following tools are required to install the battery pack NOTE Use properly insulated tools to prevent accidental electric shock or short circuits If insulated tools are not available cover the entire exposed metal surfaces of the available tools except their tips with electrical tape 3 4 Safety Gear It is recommended to wear the following safety gear when dealing with the battery pack ecoline w...

Page 13: ...les and one communication cable for each battery package Grounding cable Grounding cables use 10AWG yellow green cables UE 24Li2900WH modules grounding is based on metal directly touch between the module s surface SGCC and rack s surface If uses normal rack may need to remove the paint at the corresponding place Or install a grounding cable to the grounding point of the modules ecoline www masterb...

Page 14: ...llation location meets the following conditions The area is completely waterproof The floor is flat and level There are no flammable or explosive materials The ambient temperature is within the range from 0 C to 50 C The temperature and humidity are maintained at a constant level There is minimal dust and dirt in the area CAUTION If the ambient temperature is out of the operating range the battery pa...

Page 15: ...esa Calle Dehesa Vieja 2 28052 Madrid España Tel 34 918 021 649 Fax 34 917 750 542 info masterbattery es 15 Installation A Put battery modules into cabinet and connect the cables ecoline www masterbattery es en UE 24Li2900WH ...

Page 16: ...Área Industrial La Dehesa Calle Dehesa Vieja 2 28052 Madrid España Tel 34 918 021 649 Fax 34 917 750 542 info masterbattery es 16 ecoline www masterbattery es en UE 24Li2900WH RS485 communication ...

Page 17: ... the cables between battery modules If use 4 Connect the cables to inverter The power cables current capacity is 120 A peak If the battery string s current over this limit must configure 2 pairs of external power cables to reach 240 A If nominal current of battery system is higher than 100 A it is suggested to use 2 pairs of cables 5 There shall be a manual disconnecting device breaker etc between...

Page 18: ...nication cable check the ADD switch 1 Switch the breaker between battery system and inverter 2 Switch power on Switch on all the battery modules 3 The one connects communication cable to inverter is the Master Battery Module others are slaves 1 master battery configure with maximum 19 slave batteries 4 Press the Start Button SW of master battery to power on all the battery LED light will be on afte...

Page 19: ...Tel 34 918 021 649 Fax 34 917 750 542 info masterbattery es 19 ecoline www masterbattery es en UE 24Li2900WH ecoline ecoline ecoline ecoline ecoline ecoline ecoline ecoline If all the battery LED lights on and then off which means the battery system is good and working ...

Page 20: ...tion To move battery to the normal operating temperature range between 10 C and 55 C b Current If current is 100 A battery protection will turn on Solution Check whether current is too large or not if it is to change the settings on power supply side c High Voltage If charging voltage above 28 5 V battery protection will turn on Solution Check whether voltage is too high or not if it is to change ...

Page 21: ... NOTE Damaged batteries may leak electrolyte or produce flammable gas If such damage occurs please contact Master Battery info masterbattery es 7 Important Notice The recommended charge discharge capacity of these batteries is 0 5C 25 or 37 Amp depending on the model allowing a capacity of 1C 50 or 75 Amp depending on the model and a maximum charge discharge capacity of 90 100 Amp in depending on t...