18 | uponorpro.com
Toolbox menu
The Toolbox menu is a location for system information and Test functions. If any errors are
present on the system, they will be located at the beginning of this menu.
Field
Range
Access Description
Set to
Installer (INST)
User (USER
Default = INST
User
Installer
ACCESS LEVEL
— Selects the access level
of the control, which determines which menus
and items are available.
Conditions:
Adjustable only when control
switch setting is set to UNLOCK.
Software
J1236A
Type 1058
User
Installer
SOFTWARE VERSION AND TYPE
NUMBER
— Selects the access level of the
control, which determines which menus and
items are available.
Not applicable
Installer
FACTORY DEFAULTS
— Loads the factory
default settings. Press ENTER to load defaults.
See
Troubleshooting
Guide on p. 30
Installer
HISTORY - 1 THROUGH 5
— Displays a
history of any past errors that have occurred
on the system. Will clear after 30 days, or
press Up and Down buttons for one second to
manually clear. The last five history items will
display if present.
Display menu
The Display menu selects the temperature units and backlight options.
Field
Range
Access Description
Set to
or ºC
Default = ºF
User
Installer
UNITS
— Selects Fahrenheit or Celsius as the
temperature units.
ON,
ON MELT,
OFF
Default =
ON MELT
User
Installer
BACKLIGHT
— Selects how the display
backlight operates.
ON = Always on
ON MELT = On when melting, off when not
melting
This provides a visual indicator to occupants that
the snow melting system is currently melting.
OFF = Always off