Single-zone snow melt control installation and operation manual | 17
Monitor menu
The Monitor menu provides information about the system’s operation and performance.
The Monitor menu is not available when the Application Mode is set to the Pavement
Snow and Ice Sensor.
Field
Range
Access Description
Set to
0 to 9999
hours
User
Installer
HEAT HOURS
— Records the number of running
hours since the item was last reset. Touch the
number and then the ENTER key to reset to zero.
0 to 9999
hours
Installer
HEAT CYCLES
— Records the numbers of
cycles of the heat relay since the item was last
reset. Touch the number and then the ENTER
key to reset to zero.
0 to 9999
hours
User
Installer
SYSTEM PUMP HOURS
— Records the system
pump running hours since the item was last reset.
Touch the number and then the ENTER key to
reset to zero.
Conditions:
Auxiliary Relay is set to SYS
(system pump).
-58 to 167ºF
(-50.0 to
75.0ºC)
Installer
SLAB HIGH
— Records the highest slab
temperature since the item was last reset. Touch
the number and then the ENTER key to reset.
Conditions:
Sensor is set to the Pavement Snow
and Ice Sensor or Slab Sensor is set to On.
-58 to 167ºF
(-50.0 to
75.0ºC)
Installer
SLAB LOW
— Records the lowest slab
temperature since the item was last reset. Touch
the number and then the ENTER key to reset.
Conditions:
Snow/Ice Sensor is set to the
Pavement Snow and Ice Sensor or Slab Sensor
is set to On.
-58 to 212ºF
(-50.0 to
100.0ºC)
Installer
OUTDOOR HIGH
— Records the highest outdoor
temperature since the item was last reset. Touch
the number and then the ENTER key to reset.
-58 to 212ºF
(-50.0 to
100.0ºC)
Installer
OUTDOOR LOW
— Records the lowest outdoor
temperature since the item was last reset. Touch
the number and then the ENTER key to reset.
-58 to 212ºF
(-50.0 to
100.0ºC)
Installer
SUPPLY HIGH
—Records the highest supply
temperature since the item was last reset. Touch
the number and then the ENTER key to reset.
Conditions:
Application Mode is set to PWM
or Boil.
-58 to 212ºF
(-50.0 to
100.0ºC)
Installer
SUPPLY LOW
— Records the lowest supply
temperature since the item was last reset. Touch
the number and then the ENTER key to reset.
Conditions:
Application Mode is set to PWM
or Boil.