4
KEY FEATURES
A. FULL DATA Reporting. Compatible with most alarm panels using Contact ID
(SIA DC-05 Standard), SIA FSK Level 1 (SIA DC-03 Standard), DMP, Modem IIe/
IIIa
2
or 4/2 digital dialer formats. All information sent by the alarm panel in these
formats (account number, zone information, User IDs, etc.) will be sent to the
central station using the CDMA network.
B. Power Requirements: Requires constant 12V DC power from a power supply,
battery, or alarm panel with a constant 200 mA and a peak 600 mA for one second
during transmission.
C. Panel to CDMAEX Cable Supervision. Can be configured to Monitor continuity
of the cable connecting the panel’s telephone dialer to the CDMAEX. This feature is
activated through the website www.uplink.com or by calling Uplink Customer Service:
1-888-9-UPLINK
(1-888-987-5465)
D. Input. The CDMAEX has one programmable input. This input can be
programmed to one of the following functions via the website:
• Standard Input
• Sampled Siren
• Pulse Counter
• Timed Bell (Default Configuration)
E. Output. The CDMAEX has one programmable relay output. This output can
be programmed to activate upon the occurrence of one or more of the following
trouble conditions:
• Low DC Input Voltage
• Cable Supervision Trouble (Panel to CDMAEX)
• Loss of Cellular Service
• CDMAEX Disabled (via website command)
• Failure to receive ACK from Central Station
• Watchdog Circuit Trouble
• GPRS Network Loss
• Total Failure
F. Uplink Remote. The output may also be used in conjunction with Uplink Remote
to activate a keyswitch zone for remote arming and disarming of the alarm panel.
CDMA Primary Cellular
Alarm Communicator
®
CDMAEX