16
CDMA Primary Cellular
Alarm Communicator
®
CDMAEX
INSTALLATION (cont.)
E. Connecting the CDMAEX to the Alarm Panel
1. First, remove DC power from the CDMAEX, and then proceed as follows:
2. Panel Connections
Connect the alarm panel’s telephone output to the CDMAEX with an
appropriate cable. On the CDMAEX’s side, the cable should use an RJ45 plug
and be connected into Jack JP3.
3. Output
The CDMAEX has one relay output that can be used to activate a
keyswitch zone on the alarm panel for arm/disarm with Uplink Remote or
for other local purposes. Decide on how to use this output (see section 6.
Programming) then wire it from the terminal strip to the external panel
or device:
Output #1 Terminals: OUT1+ and OUT1-
The default state for this Output is as follows:
OUTPUT
DEFAULT STATE
DEFAULT DEFINITION
#1
Configurable - normally
open
no mapping
See Figure 2 as an example of how to connect the CDMAEX to the alarm panel.
IMPORTANT: Make all of the connections to the CDMAEX in the powered down
state. Once all of the connections have been established, turn power on.