Post-connection checks
Check the items listed in the table after connecting the oven to the gas utility or after adjusting to a new type of gas.
¥
Check:
Check result
The air-tightness of the gas circuit using NON-CORROSIVE foam substances.
Never use flames!
1RPLQDOVXSSO\SUHVVXUHXVLQJDIOXLGSUHVVXUHJDXJHHJDHOHFWULFPDQRPHWHU
,IYDOXHVGHWHFWHGGHYLDWHIURPPLQDQGPD[SUHVVXUHOLVWHGLQWKH´7HFKQLFDO
6SHFLILFDWLRQVµVKHHW
CHART A
DWWDFKHGWRWKHDSSOLDQFHFRQWDFWWKHORFDO
gas utility company
.
mbar.........................
The gas valve outflow pressure.
Compare values with those of
“
Table D - Gas valve outflow pressure”
at
page
29
.
min mbar................
max mbar................
The values of CO - CO
2
of the exhaust gas and record values detected. The
burner settings must be checked and adjusted by a specialised technician for
values of non-diluted CO greater than 1000 ppm.
ppm.........................
If the tests were positive, power and start-up the appliance, and through the air vents, check the points listed in
the table:
¥
Checks:
Check result - OK
Proper burner ignition
Bright blue flame with no yellow tips
Gas exhaust pipe and air vents clean and free of obstructions
Instruct the user about the basics of safe oven operation with respect to this installation, use and maintenance
manual.
BakerTop
™
ChefTop
™
English
31