9100 on mounting bracket (available as accessory) 

Page 10 

19. Accessories & spares: 
 

Silicone Tubing IDØ1.0mm complete with connectors..................... Cat.No.9000.504 
Silicone Tubing IDØ2.0mm complete with connectors..................... Cat.No.9000.505 
Silicone Tubing IDØ3.0mm complete with connectors..................... Cat.No.9000.510 
 
Santoprene Tubing IDØ1.0mm complete with connectors ............... Cat.No.9000.501 
Santoprene Tubing IDØ2.0mm complete with connectors ............... Cat.No.9000.502 
Santoprene Tubing IDØ3.0mm complete with connectors ............... Cat.No.9000.518 
 
Santoprene tubing ID Ø1.00mm1meter running length ................... Cat.No.9000.521 
Santoprene tubing ID Ø2.00mm1meter running length ................... Cat.No.9000.506 
Santoprene tubing ID Ø3.00mm1meter running length ................... Cat.No.9000.515 
 
Silicone tubing ID Ø1.00mm1meter running length ......................... Cat.No.9000.507 
Silicone tubing ID Ø2.00mm1meter running length ......................... Cat.No.9000.509 
Silicone tubing ID Ø3.00mm1meter running length ......................... Cat.No.9000.508 
 
Tube clamp for continuous Ø1.0mm tube (set of 2) ........................ Cat.No. 9000.601 
Tube clamp for continuous Ø2.0mm tube (set of 2) ........................ Cat.No. 9000.602 
Tube clamp for continuous Ø3.0mm tube (set of 2) ........................ Cat.No. 9000.603 
 
Unoverse 9100 wall mounting bracket/stand ................................... Cat.No.9100.001 
Foot Switch ............................................................................................ Cat. No 6013 
8 way dispense comb ........................................................................... Cat. No. 3022 
Yellow tip 1-200µl ................................................................................. Cat. No. 3530 
Tip holder support ......................................................................... Cat.No. 9100.3003 
 
 

 

 

 

 

9000.601 

9000.602 

9000.603 

3022 

9000.502 

9100.001 

Summary of Contents for BOXER 9100

Page 1: ...1 0mm complete with connectors Cat No 9000 504 Silicone Tubing IDØ2 0mm complete with connectors Cat No 9000 505 Silicone Tubing IDØ3 0mm complete with connectors Cat No 9000 510 Santoprene Tubing IDØ1 0mm complete with connectors Cat No 9000 501 Santoprene Tubing IDØ2 0mm complete with connectors Cat No 9000 502 Santoprene Tubing IDØ3 0mm complete with connectors Cat No 9000 518 Santoprene tubing...

Page 2: ...ical compatibility chart 1 A Unpacking Remove the packing materials unpack the pump controller and the power supply unit Make sure that you have got all the components as specified in Box Contains last page of this manual Please contact your supplier if you notice any one of the components is missing or damaged Note Do not attempt to assemble a unit using damaged components Retain the packaging so...

Page 3: ... pressure by lifting the pressure lever 3 C Replacing the tube Tube need replacing when worn out or wherever you intend to change the dispense volume range in which you work for smaller or larger dispense volumes Lift the pressure lever and replace the tube making sure that you have installed the tube centrally and that the tube is fully engaged by the tube guides Page 2 Pressure lever Clamp 4 The...

Page 4: ...t be entered in R2 R3 Working with low volume dispenses with large diameter tube will reduce both precision and accuracy of dispenses Using the U D keys scroll to the screen displaying Range Enter Press Enter Using the U D keys choose the range corresponding to your tube diameter and press Enter The display will show the last volume you worked with at that particular range 8 Gravimetric pump calib...

Page 5: ...ered volume in the reversed direction Page 7 13 Interval Dispense You can set the unit to dispense any volume for a number of times in predefined intervals This feature is useful in repeatable operations either in manual mode or when the dispense head is held by a robotic arm Intervals can be set between 0 5 sec to 100 minutes To set repeat dispensing 1 Using the U D keys scroll to the screen sayi...

Page 6: ...de into stored values and therefore the calculator will round up or down to the nearest whole figure 5 Q Can I leave the unit switched ON throughout the day A Yes you can The dispenser requires very little energy when the pump is not running so continuous power into the unit will not harm it 6 Q Can I dispense hot reagents using the dispenser A Yes the dispenser to works safely with media temperat...

Page 7: ...1 Santoprene tubing ID Ø2 00mm1meter running length Cat No 9000 506 Santoprene tubing ID Ø3 00mm1meter running length Cat No 9000 515 Silicone tubing ID Ø1 00mm1meter running length Cat No 9000 507 Silicone tubing ID Ø2 00mm1meter running length Cat No 9000 509 Silicone tubing ID Ø3 00mm1meter running length Cat No 9000 508 Tube clamp for continuous Ø1 0mm tube set of 2 Cat No 9000 601 Tube clamp ...

Reviews: