122
WM-#26
NOT USED
WM-#27
NOT USED
WM-#28
SIMPLE CONDIMENT PLU ENTRY IS PROHIBITED
Main PLU not entered yet.
WM-#29
SIMPLE CONDIMENT PLU INPUT IS COMPULSORY
(can be released temporarily by using
OFF COMPULSORY
key)
WM-#30
PLU NOT FOUND
Enter correct PLU code or program PLU code.
WM-#31
CHECK-OUT BILL ISSUE IS COMPULSORY
Press
CHECK-OUT BILL
key. (can be canceled by using
BILL CANCEL
key)
WM-#32
SLIP PAPER HAS NOT BEEN INSERTED
WM-#33
CURRENT ITEM TRACK / CLERK INTERRUPT MEMORY IS FULL
Close the item track or the clerk's transaction temporarily by New Balance key or close it by a media key.
WM-#34
ENTIRE ITEM TRACK / CLERK INTERRUPT MEMORY IS FULL
- close the item track or the clerk's transaction temporarily by New Balance key, then
- close another item track, or
- another clerk's transaction by a media key to secure additional item track memory, or
- do the previous balance key operation.
This message is also displayed when all item tracks are used under the limited automatic item track number.
CHECKING THE NUMBER OF BLOCKS OF ITEM TRACK / CLERK INTERRUPT MEMORY
This function is used for checking the number of remaining blocks.
- Set the control key to X position.
- Press
ITEM TRACK #
key.
- The number of remaining blocks is displayed.
After the item track or the clerk's transaction has been closed by a media key, the occupied blocks will become
free. To secure the memory of currently occupied transactions, a new transaction can not be opened, even if a few
blocks remain.
The maximum number of item tracks or clerk interrupt memories, that can be handled, depends on the number of
items registered per item track or clerk interrupt memory.
# of blocks
- 384 blocks are available.
One transaction always occupies one block.
- Up to 24 blocks (max. 359 items) are used for one transaction.
1st block can memorize 7 items, and 2nd ~ 24th blocks 16 items per block.
# of item tracks/clerk interrupt memories
Up to 384 item tracks/clerk interrupt memories can be used if 7 items each is registered.
Up to 192 item tracks/clerk interrupt memories can be used if 23 items each is registered.
Up to 128 item tracks/clerk interrupt memories can be used if 39 items each is registered.
Up to 96 item tracks/clerk interrupt memories can be used if 55 items each is registered.
Up to 76 item tracks/clerk interrupt memories can be used if 71 items each is registered.
Up to 64 item tracks/clerk interrupt memories can be used if 87 items each is registered.
Up to 32 item tracks/clerk interrupt memories can be used if 183 items each is registered.
Up to 16 item tracks/clerk interrupt memories can be used if 359 items each is registered.
WM-#35
NEW BALANCE CLOSING OF ITEM TRACK IS COMPULSORY
(can be released temporarily by using
OFF COMPULSORY
key)
WM-#36
NEW BALANCE CLOSING OF ITEM TRACK IS PROHIBITED
WM-#37
ITEM TRACK # INPUT IS COMPULSORY
(can be released temporarily by using
OFF COMPULSORY
key)
WM-#38
TABLE # INPUT FOR ITEM TRACK IS COMPULSORY
(can be released temporarily by using
OFF COMPULSORY
key)
WM-#39
COOKING MESSAGE INPUT IS COMPULSORY
(can be released temporarily by using
OFF COMPULSORY
key)
WM-#40
ITEM / AMOUNT TRACK TRANSFER IS PROHIBITED
WM-#41
ITEM TRACK # NOT FOUND