WATER AND DRAINAGE CONNECTION
WARNING!
Installation of the unit must be done by personnel qualified to work with electricity and plumbing
improper installation can cause injury to personnel and /or damage to equipment.
Unit must be installed in accordance with all applicable codes.
A closure valve must be inserted between the equipment and the water mains. The upstream water
inlet must meet current regulations.
The water inlet and outlet are located at the back of the oven.
The water pressure must be within 50-300kPa range.
If the mains pressure does not fall within the range indicated below, a pressure reducer must be installed
upstream from the oven.
We recommend using softened water with a hardness level between 2 and 5°f.
We recommend a flexible hose to absorb small pressure peaks.
Run water through the pipes before making the connection.
Drainage takes place through a heat-resistant inflexible pipe
Drainage water should lead to the drainage system by constant descent, and with a funnel or siphon
inserted. It is forbidden to reduce the diameter of the pipe.
CAUTION!
Incorrect drainage may lead to unpleasant odors in the cooking chamber!
ELECTRICAL CONNECTION
WARNING!
Installation of the unit must be done by personnel qualified to work with electricity and plumbing
improper installation can cause injury to personnel and /or damage to equipment.
Unit must be installed in accordance with all applicable codes.
Check the oven setup, comparing the type of mains current and voltage available with the levels
shown on the serial plate.
Remove the terminal board cover, insert the cable in the holder and connect each wire to the
corresponding terminal.
Once the cable is connected to the terminal board, tighten the cable holder on the back of the
equipment and close the cover.
The appliance, when installed, must be electrically grounded in accordance with local codes, or in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code,
CSA C22.2, as applicable.
The oven must also be included in an efficient equipotent system.
This connection is made using the special terminal marked with the symbol
, located at the back.
Summary of Contents for RDR-GAS
Page 1: ...RDR GAS ROTATING DOUBLE RACK BAKERY OVEN ...
Page 8: ...Page 8 VIEW OF THE EQUIPMENTS VOLUMES AND CONNECTIONS OF GAS VERSION OF UNIT RDRG ...
Page 40: ...Page 40 ELECTRIC DIAGRAM ...
Page 41: ...Page 41 ...
Page 42: ...Page 42 ...
Page 43: ...Page 43 ...
Page 47: ...Page 47 Phone 603 458 7690 Address P O Box 1062 Windham NH 03079 ...