28
The fan must be installed by an electrician or a
qualified person.
The fan must be connected to a 220-240V power
supply.
All electrical work must be carried out after
disconnecting the electrical current by turning off
the switch.
The fan must be grounded.
The fan must be installed so that the blades are at
least 2.3 meters above the ground.
The fan must be suspended from a structure
capable of supporting a weight of at least 45 kg.
The fixture must be able to support the weight of
the moving fan without moving.
Make sure that at the installation site the blades do
not come into contact with any objects. Always
leave a minimum clearance of 150 mm from the tip
of the blades to the wall or ceiling. Keep in mind
that the larger the space, the better the airflow of
the fan.
For indoor use only. Do not use in an open space
or where it can be exposed to water or moisture.
Do not connect the fan motor to a current
regulator. It could give unsatisfactory performance
(engine buzzing) and cause engine damage.
This appliance is not intended for use by persons
(including children) with reduced physical, sensory,
or mental capabilities or lack of knowledge, unless
they are receiving supervision or instruction
regarding the use of the appliance by a responsible