background image

288-3100-02H

UNIVERSAL FIVE YEAR LIMITED WARRANTY

Universal Security Instruments, Inc. ("Universal") warrants your Universal
product to be free from defects in material and workmanship for a period
of  five (5) years from the date of purchase.

 This warranty applies only to

the original consumer purchaser and only to products used in normal
residential use and service. If this product is found to be defective, Universal's
only obligation, and your exclusive remedy, is the repair or replacement of
the product, at Universal's discretion, provided that the product has not
been damaged through misuse, abuse, accident, modifications, alteration,
neglect or mishandling. This Warranty shall not apply to any product which
is found to have been improperly installed, set-up, or used in any way not in
accordance with the instructions supplied with the product. This warranty
shall not apply to any batteries used in the product or to any damage which
may be caused by such batteries. For repair or replacement, send the
defective product to Universal Security Instruments, Inc. at 

11407 Cronhill

Drive, Suite A

, Owings Mills, Maryland 21117, postage prepaid with a

payment of $5.00 to cover the costs of return postage and handling. You
must include a proof of purchase (receipt) along with the returned product.

UNIVERSAL DOES NOT WARRANT AND SPECIFICALLY DISCLAIMS ANY
WARRANTY, WHETHER EXPRESS OR IMPLIED, OF FITNESS FOR A
PARTICULAR PURPOSE, OTHER THAN THE WARRANTY CONTAINED
HEREIN. NO IMPLIED WARRANTY ON THIS PRODUCT, CREATED BY STATE
LAW, SHALL EXTEND BEYOND THE TERM OF THIS WARRANTY UNLESS
SUCH LAW OTHERWISE PROVIDES. UNIVERSAL SPECIFICALLY DISCLAIMS
ANY LIABILITY AND SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR
INCIDENTAL LOSS OR DAMAGE, INCLUDING, BUT NOT LIMITED TO,
DAMAGES TO ANY EQUIPMENT WITH WHICH THIS PRODUCT IS USED.

Some states do not allow the exclusion or limitation of incidental or
consequential damages so the above limitations or exclusions may not
apply to you.

No agent, representative, dealer, or employee of the company has the
authority to increase or alter the obligations or terms of this Warranty.

This Warranty gives you specific legal rights and you may also have other
rights which vary from state to state.

This Warranty is only valid for merchandise purchased from outlets in the
United States and Canada.

©1996 UNIVERSAL SECURITY INSTRUMENTS, INC,. Rev. 2009

Printed in China

11407 Cronhill Drive, Suite A

Owings Mills, Maryland 21117 USA

Visit Us on the Web! 

 

www.SmokeAlarms.com

Summary of Contents for SS-785

Page 1: ...R INSURANCE Homeowners and renters alike should continue to insure their lives and properties SMOKE ALARMS CANNOT WORK WITHOUT POWER Battery operated units cannot work if the batteries are missing disconnected or dead if the wrong type of batteries are used or if the batteries are not installed correctly AC only powered units cannot work if the AC power is cut off for any reason If you are concern...

Page 2: ...102 mm vertically to the peak Sloped Ceilings Shed Ceilings Smoke alarms or smoke detectors mounted on a sloped ceiling having a rise greater than 1 ft in 8 ft 1 m in 8 m horizontally shall be located within 36 in 914 mm of the high side of the ceiling but not closer than 4 in 102 mm from the adjoining wall surface Tray Shaped Ceilings Smoke Alarms or smoke detectors shall be installed on the high...

Page 3: ...e beginning installation Failure to turn off the power before installation may result in serious electrical shock injury or death TAMPER LOCKING PIN To make your smoke alarm somewhat tamper resistant a locking pin has been provided Using this pin will deter children and others from removing the alarm from the mounting ring To use the pin insert it into the hole in the side of the alarm after it ha...

Page 4: ... alarm event initiates the alarm The yellow wire is used only for multiple station operation with UNIVERSAL models only Connecting this yellow wire to any other circuits may result in damage When smoke alarms are interconnected all units must be powered from a single AC branch circuit If local codes do not permit be sure the neutral wire is common to both phases The maximum wire run distance betwe...

Page 5: ...witch accurately tests the unit s operation as required by Underwriters Laboratories Inc UL BACKUP BATTERY REPLACEMENT Model SS 790 only Disconnect AC power before changing battery Shock hazard exists if AC power is miswired The smoke alarm uses a 9 Volt carbon zinc battery The battery should last for at least one year under normal operating conditions The smoke alarm has a low battery indicator a...

Page 6: ...is all right to do so NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED PROTECTION For your information the National Fire Protection Association s Standard 72 reads as follows 11 5 1 One and Two Family Dwelling Units 11 5 1 1 Smoke Detection Where required by applicable laws codes or standards for the specified occupancy approved single and multiple station smoke alarms shall be installed as follows 1...

Page 7: ...repaid with a payment of 5 00 to cover the costs of return postage and handling You must include a proof of purchase receipt along with the returned product UNIVERSAL DOES NOT WARRANTAND SPECIFICALLY DISCLAIMSANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NOIMPLIEDWARRANTYONTHISPRODUCT CREATEDBYSTATE LAW SHALLEXTEND BEYOND THE T...

Reviews: