![Universal HP-100NI Owner'S Manual Download Page 19](http://html1.mh-extra.com/html/universal/hp-100ni/hp-100ni_owners-manual_845879019.webp)
Page 19 of 26
5 -Install the Locking Collar.
6 -Tighten the (2) Locking Collar Set Screws
while holding pressure on the Locking Col-
lar.
7 -Test the assembly by installing the Ink Roller
Axle and attempting to wiggle the end of
the axle.
Set the assembly on the bench with the knurled end
of the Eccentric Adjusting Knob down. Using your
fingertips, press down hard on the Locking Collar. It
is important that the Locking Collar is tight against
the Side Frame for this assembly to work properly.
The Ink Roller Axle must be held rigidly in position or
the Ink Roller will not be parallel to the printing dies.
If there is any play in the Axle, repeat Step 6 and
apply greater pressure to the Locking Collar before
tightening the set screws.
If you have to release the pressure against the
Locking Collar in order to access the other set
screw, reapply pressure before tightening the final
set screw.
8 -Snug the Tension Adjusting Set Screw as
necessary to provide resistance when turn-
ing the Eccentric Adjusting Knob.
Figure 53
Figure 54
Figure 55
Figure 56
The nylon tip of the set screw should be tight enough
to prevent the Ink Roller Axle from moving out of
adjustment during operation.
MAINTENANCE