6. Connect remote control circuitry (if used) to the rear panel connector, J4, as described in Section 5.
7. With the breaker in the OFF position and the building power OFF, connect AC power lines to the
unit. It is very important to use 600V (UL1015) insulated stranded wire of sufficient gauge (#6
AWG or greater) to handle the full load line current. Strip about 0.4 inch (~1 cm) of insulation
from the wires before inserting them into the terminal block.
Phase sequence is not critical on this three phase switching power supply.
8. When all of the connections have been double checked, apply AC power from the source circuit
breaker box and turn the front panel circuit breaker ON. The unit is now ready for high voltage
operation.