Page 7

BATTERY REPLACEMENT

The smoke alarm uses a 9 Volt battery. The battery should last for at least one year under normal
operating conditions. The smoke alarm has a low battery indicator, an audible beep or chirp. It will
operate at approx. 40 second intervals for a minimum of 7 days. When this indication occurs, replace
the battery with an Alkaline type (Eveready Energizer #522, Duracell #MN1604) or Lithium type
(Ultralife U9VL-J or Ultralife V9VL-J-P) from your local retailer.

LITHIUM Battery Models only - The LITHUM battery is warranted to last for 10 years under normal
operating conditions. Replace the battery with only LITHIUM type: (ULTRALIFE: U9VL-J)

DEVELOP AND PRACTICE A PLAN OF ESCAPE

BASICS OF ESCAPE PLAN

o Make a floor plan indicating all doors and windows and at least two escape routes from each

room. Second story windows may need a rope or chain ladder.

o Have a family meeting and discuss your escape plan, showing everyone what to do in case of

fire.

o Determine a place outside your home where all of you can meet if a fire occurs.
o Familiarize everyone with the sound of the smoke alarm and train them to leave your home when

they hear the sound.

o Identify children's bedrooms with red stickers placed in the upper left corner of the windows. They

are available from your local fire department.

o Practice a fire drill at least every six months. Practice allows you to test your plan before an

emergency. You may not be able to reach your children. It is important they know what to do!

WHAT TO DO WHEN THE ALARM SOUNDS

o Leave immediately by your plan of escape. Every second counts, so don't waste time getting

dressed or picking up valuables.

o In leaving, don't open any inside door without first feeling its surface. If hot, or if you see smoke

seeping through cracks, 

don't open that door!

   Instead, use your alternate exit. If inside door is

cool, place your shoulder against it, open it slightly and be ready to slam it shut if heat and smoke
rush in.

o Stay close to the floor if air is smoky. Breathe shallowly through a cloth, wet if possible.
o Once outside, go to your selected meeting place and make sure everyone is there.
o Call the fire department from your neighbor's home – 

not from yours!

o Don't return to your home until fire officials say that it is all right to do so.

REPAIRS AND SERVICES

This smoke alarm contains less than 1 microcurie (37 kilobecquerel) of Americium 241, a radioactive
material. 

The distribution of these ionization-type smoke alarms is licensed by the U.S. Nuclear

Regulatory Commission; the consumer is exempt from any licensing or requirements.

 If the

smoke alarm is defective in any way, do not tamper with the smoke alarm. Return the smoke alarm
for servicing. (See warranty for instructions or in-warranty returns.) There will be a service charge for
repairing out of warranty smoke alarms.

NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED INFORMATION

For your information, the National Fire Alarm Code, NFPA 72, reads as follows:
"11.5.1 *Required Detection - Where required by applicable laws, codes, or standards for a specific
type of occupancy, approved single and multiple-station smoke alarms shall be installed as follows:
(1) *In all sleeping rooms and guest rooms
(2) *Outside of each separate dwelling unit sleeping area, within 6.4 m (21 ft) of any door to a
sleeping room, the distance measured along a path of travel
(3) On every level of a dwelling unit, including basements.
(4) On every level of a residential board and care occupancy (small facility), including basements
and excluding crawl spaces and unfinished attics
(5) *In the living area(s) of a guest suite
(6) In the living area(s) of a residential board and care occupancy"

The equipment should be installed using wiring methods in accordance with the

National Fire Protection Association's Standard 72.

(National Fire Protection Association, Batterymarch Park, Quincy, MA 02269)

Summary of Contents for MPI305

Page 1: ...Testing Maintenance 5 Quick Find Alarm Originating Feature Reset 5 Cautions Warnings 6 Battery Replacement 7 Develop and Practice a Plan of Escape 7 Operational Summary 8 Warranty Back Cover MODEL MP...

Page 2: ...FLAMMABLE MATERIALS OVERLOADED ELECTRICAL CIRCUITS CHILDREN PLAYING WITH MATCHES NATURAL CAUSES SUCH AS LIGHTNING OR ARSON FIRE PREVENTION IS YOUR BEST SAFEGUARD INSTALLING SMOKE ALARMS MAY MAKE YOU E...

Page 3: ...4 in 102 mm vertically to the peak Sloped Ceilings Shed Ceilings Smoke alarms or smoke detectors mounted on a sloped ceiling having a rise greater than 1 ft in 8 ft 1 m in 8 m horizontally shall be l...

Page 4: ...areas near dishwashers or washing machines Install at least 3 feet 0 9 meters away from these areas in areas of turbulent air such as air returns or heating and cooling supply vents smoke alarms shall...

Page 5: ...designed to minimize nuisance alarms Smoking will not normally set off the alarm unless smoke is blown directly into the smoke alarm Combustion particles from cooking may set off the alarm if the smo...

Page 6: ...and Fire Alarm is the use of the analyzer for Smoke Detectors Model 501 A or 501 A Bat Aerosol Generator Manufactured by Gemini Scientific Corp 1122 B Aster Ave Sunnyvale CA 94086 The Equivalent UL 26...

Page 7: ...nate exit If inside door is cool place your shoulder against it open it slightly and be ready to slam it shut if heat and smoke rush in o Stay close to the floor if air is smoky Breathe shallowly thro...

Page 8: ...normal operation mode or Blinks on once approx every 10 seconds silence mode Originating smoke alarm If hazard is identified please take all precautions if an alarm sounds by calling an Emergency Ser...

Page 9: ...ecting the battery to excessive humidity hot or cold conditions E Altering the battery physically in any way ULTRALIFE 9 VOLT BATTERY RETURNS To return the Ultralife Battery under warranty send batter...

Reviews: