The yellow wire is used only for multiple station operations with USI ELECTRIC or UNIVERSAL
Model alarms only. Connecting this yellow wire to any other circuits may result in damage
and alarm malfunction. When alarms are interconnected, all alarms must be powered from a
single AC branch circuit. If local codes do not permit, be sure the neutral wire is common to
both phases. The maximum wire run distance between the first and last alarm/device in an
interconnected system is 1,000 feet. NOTE: Use standard household wire (18 gauge or larger,
rated at least 300V, as required by local codes) available at all electrical supply/hardware
stores.

2.

Attach the mounting bracket to the electrical junction box.

3.

Plug the AC QUICK CONNECTOR into the alarm base. Push and twist the alarm clockwise
onto the mounting bracket.

4.

See "OPTIONAL TAMPER RESISTANT FEATURE" and "TO ACTIVATE THE LOCKING
FEATURE" instructions on Page 7.

5.

Turn on AC power and check the LED's for proper operation. The green LED should be on and
blink off approx. every 20 seconds to indicate AC power.

IMPORTANT!

The battery backup is designed to provide short-term emergency power to the Smoke, CO and Gas
Alarm. Actual backup time depends on the strength (freshness) of the battery. The battery backup
will not work unless a good battery is properly installed.

When the alarm utilizes battery backup power, the natural gas sensor will operate the alarm and will
sample less frequently to extend battery life. Natural gas could be present during this period between
samples without the alarm sounding, especially if there is a rapid buildup of natural gas.

NOTE: It is best to “reset” the alarms before initial test is performed. See Page 10 for Reset
procedures.

OPERATION, TESTING & MAINTENANCE

OPERATION:

 The alarm is operating once the AC power is connected and turned on.  When products

of combustion are sensed, the alarm sounds a loud alarm which continues until the air is cleared.
This alarm incorporates the NFPA recognized horn signal for evacuation. During smoke alarm mode,
the horn produces three beeps followed by a two second pause and then continually repeats.

READY/ACTIVE CONDITION:

 The green LED is on and blinks off once approx. every 20 seconds

to indicate the alarm is properly functioning.

LOCAL ORIGINATING SMOKE ALARM CONDITION:

 The green LED turns off and the red LED

blinks on approx. every second while the alarm emits a loud, pulsating alarm sound.

NON-ORIGINATING SMOKE ALARM CONDITION:

 The red LED is off and the alarm emits a loud,

pulsating alarm.

GREEN LED:

 The green LED blinks on approx. every 40 seconds whenever AC power is turned on.

CO ALARM:

 The alarm signal is 4 beeps, 5 second pause, repeat. The red LED blinks on in sync

with the cycle of 4 beeps.

GAS ALARM:

 The alarm signal is 1 beep, 2 second pause, repeat. The blue LED blinks on in sync

with the horn beep every second.

120 VAC 60Hz

100mA Max.

Summary of Contents for MICN102

Page 1: ...C 60 Hz 100 mAMax SECURITY INSTRUMENTS INC Table of Contents Page Alarm Limitations and Functions 2 What You Should Know About CO 3 What You Should Know About Natural Gas 3 Basic Safety Information 5...

Page 2: ...SIONS ESCAPING GAS IMPROPER STORAGE OF FLAMMABLE MATERIALS OVERLOADED ELECTRICAL CIRCUITS CHILDREN PLAYING WITH MATCHES NATURAL CAUSES SUCH AS LIGHTNING OR ARSON FIRE PREVENTION IS YOUR BEST SAFEGUARD...

Page 3: ...ical problems may consider using warning devices which provide audible and visual warnings for carbon monoxide concentrations under 30 ppm IMPORTANT CONSIDERATIONS YOUR COMBINATION SMOKE CO AND NATURA...

Page 4: ...ceiling shall be located within 36 in 914 mm horizontally of the peak but not closer than 4 in 102 mm vertically to the peak Sloped Ceilings Shed Ceilings Smoke alarms or combination alarms mounted on...

Page 5: ...to detect any other gas Carbon monoxide and natural gas may be present in other areas The Smoke CO and Natural Gas Alarm will only indicate the presence of CO or natural gas which reaches the sensor D...

Page 6: ...nted alarms can occur if an alarm is placed directly next to a fuel burning source Ventilate these areas as much as possible If you must install the alarm near a cooking or heating appliance install a...

Page 7: ...e alarm in the direction indicated by the TWIST TO REMOVE arrow on the side of the alarm base OPTIONAL TAMPER RESISTANT FEATURES There are two separate tamper resistant locking features provided for t...

Page 8: ...sing models within an interconnected system The following alarms cannot reset units on an interconnected system USI 7795 CD 9795 USI 7385 USI 7390 USI 7485 USI 7490 CD 9385 CD 9390 CD 9485 CD 9490 The...

Page 9: ...rm utilizes battery backup power the natural gas sensor will operate the alarm and will sample less frequently to extend battery life Natural gas could be present during this period between samples wi...

Page 10: ...ach alarm event TESTING Test by pushing the Test button on the alarm cover until the alarm sounds then release The alarm will sound 3 beeps approx 2 second pause 3 beeps approx 6 second pause 4 beeps...

Page 11: ...etected If CO levels drop below alarm levels the alarm will remain silent and return to normal operation If CO levels remain constant or increase this indicates a potentially dangerous situation and t...

Page 12: ...y damage or set fire to the alarm or to your home The built in test switch accurately tests the unit s operation as required by the UL 217 UL 2034 and UL 1484 Standards NEVER use vehicle exhaust Exhau...

Page 13: ...self diagnostic test reveals a malfunction immediately have the unit replaced see last page for warranty information Smoke CO and Natural Gas alarms can only sense CO which reaches the alarm s sensor...

Page 14: ...nsumer is exempt from any licensing or requirements Simultaneous operation of several fuel burning appliances competing for limited internal air Vent pipe connections vibrating loose from clothes drye...

Page 15: ...sleeping area within 6 4 m 21 ft of any door to a sleeping room the distance measured along a path of travel 3 On every level of a dwelling unit including basements 4 On every level of a residential...

Page 16: ...ff Blinks On in sync with the 1 beep Condition Originating GAS Alarm Recommendation If hazard is identified take all precautions if an alarm sounds by calling an Emergency Service and getting out of t...

Page 17: ...enced for a 10 hour period for up to 20 days After 20 days the warning cannot be silenced The alarm should be replaced immediately Silent alarmed previously Off and Blinks On approx every 5 seconds un...

Page 18: ...ECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE LAW SHALL...

Reviews: