Page 17
THIS PRODUCT IS LISTED TO UL STANDARD FOR SAFETY, UL 217, UL 2034 and UL 1484
GAS
BLUE LED
AUDIBLE & VISUAL SIGNALS
HORN
OPERATIONAL SUMMARY
(continued)
CONDITION / RECOMMENDATION
Horn has
stopped
sounding
Off
Off
Condition:
Latching smoke LED indicator. The alarm has
previously detected smoke and had alarmed.
Recommendation:
Follow the reset instructions to remove
the latching LED.
CO
RED LED
Silent
(alarmed
previously)
Off and Blinks
On approx
every 5
seconds
until reset
Off and Blinks
On approx
every 5
seconds
until reset
Condition:
Alarm needs to be reset due to abnormal operation/
previous alarms.
Recommendation:
To reset the alarm, hold the Test/Silence
button for 10 seconds or until the blue LED turns on. This will
clear the alarm origination and latching LEDs. Reset after each
alarm event.
Horn has
stopped
sounding
Off
Off
Condition:
Latching CO LED indicator. The alarm has
previously detected CO and had alarmed.
Recommendation:
Follow the reset instructions to remove
the latching LED.
Horn has
stopped
sounding
Off
Off
Condition:
Latching GAS LED indicator. The alarm has
previously detected GAS and had alarmed.
Recommendation:
Follow the reset instructions to remove
the latching LED.
1 Chirp
approx.
every 40
seconds
Off
Off
Condition:
Low battery.
Recommendation:
Check to make sure a battery is present
in the drawer, the battery activation pull tab has been completely
removed, battery polarity is correct and the battery terminals
are making contact with the smoke alarm contacts in the battery
drawer. If chirp continues, replace the 9V battery (see User’s
Manual for recommended battery types).
3 Chirps
approx.
every 20
seconds
Off
Off
Condition:
Sensor Trouble/Sensor End-of-Life Alarm.
Recommendation:
Reset the alarm. If this does not clear the
problem, replace alarm.
2 Chirps
approx.
every 20
seconds
Off
Off
Condition:
Product End-of-Service Life Notification.
Recommendation:
Replace the alarm immediately. The product
end-of-service life notification can be temporarily silenced for a
10 hour period for up to 20 days. After 20 days, the warning
cannot be silenced. The alarm should be replaced immediately.
Silent
(alarmed
previously)
Off and Blinks
On approx.
every 5
seconds until
reset
Condition:
Previous alarm condition at unidentified source.
Recommendation:
QUICK FIND
®
Alarm Origination - In an
interconnected system consisting of any of these models: 5304,
MI106, MDS107, MCN108, MICN109, MDSCN111 and MP117,
it may be difficult to determine which alarm initiated the alarms
to sound. The QUICK FIND
®
feature will allow you to immediately
locate the originating alarm once the alarms have stopped
sounding. To initiate QUICK FIND
®
, press the Test/Silence
button on any alarm. After releasing the button, the test sequence
on this alarm will begin and last 5-20 seconds and then stop. The
specific horn pattern is designated by the alarm type. Once this
test sequence ends, the
originating alarm
continues to sound
for approx 50 seconds, which provides ample time to locate the
originating alarm. Remember to reset (see Page 10) the originating
alarm in order to clear the QUICK FIND
®
alarm origination and
to return your system to normal operation. Refer to the
Interconnect Compatibility section of this manual (see Page 8)
for additional information. In a non-interconnected installation, it
is necessary to test each alarm to determine the originating
alarm.
Off and
Blinks On
approx.
every 5
seconds
until reset
* During 120 volt operation On and Blinks Off approx. every 20 seconds.
During 9 volt (DC backup) operation, blinks On approx. every 40 seconds.
POWER
GREEN LED
On and Blinks
Off approx
every 20
seconds
On and Blinks
Off approx
every 20
seconds
On and Blinks
Off approx
every 20
seconds
On and Blinks
Off approx
every 20
seconds
On and Blinks
Off approx
every 20
seconds
On and Blinks
Off approx
every 20
seconds
On and Blinks
Off approx
every 20
seconds
On and Blinks
Off approx
every 20
seconds
SMOKE
RED LED
Off and Blinks
On approx
every 5
seconds
until reset
Off and Blinks
On approx
every 5
seconds
until reset
Off or Blinks
On approx
every 5
seconds
until reset
Off
Off
Off
Off or Blinks
On approx
every 5
seconds
until reset
Off or Blinks
On approx
every 5
seconds
until reset