ALARM LIMITATIONS AND FUNCTIONS

This Combination Smoke/Carbon Monoxide (CO) and Natural Gas alarm requires constant 120
VAC power to operate properly.

There are three basic smoke alarm types: 

IoPhic

®

Ionization

 and 

Photoelectric

.

IoPhic

®

 is an ionization alarm containing patented Universal Smoke Sensing Technology

TM

IoPhic

®

 alarms

are very effective at detecting fast flaming fires and also respond very quickly to slow smoldering fires - up
to 87% faster than the maximum allowable alarm limit (UL217 Smoldering Smoke Test on 5/26/2010,
Underwriters Laboratories Project #09CA38078).

Ionization

 smoke alarms are typically more effective at detecting fast flaming fires - fires which consume combustible

materials rapidly and spread quickly. Sources of these fires may include paper burning in a wastebasket, or kitchen
grease fires.

Photoelectric

 smoke alarms, on the other hand, are typically more effective at detecting slow smoldering fires - fires

which burn for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches
or bedding.
Installing 

IoPhic

®

 smoke alarms ensures maximum detection of both types of fires from a single alarm, while eliminating

the need for a combination of ionization and photoelectric smoke alarms.
The enclosed alarm is a 

Smoke, CO and Natural Gas

 alarm.

®

SMOKE ALARMS WILL NOT WORK DURING A LOSS OF POWER. SINCE A SMOKE ALARM WILL
NOT WORK WITHOUT POWER, having an alarm(s) that works from two completely different power
sources, such as an AC direct wire with battery backup smoke alarm, can give you an extra measure of
protection in case of an AC power failure or a dead battery. Battery operated alarms cannot work if the
batteries are missing, disconnected or dead, if the wrong type of batteries are used or if the batteries are
not installed correctly. AC (only) powered alarms cannot work if the AC power is cut off for any reason. If
you are concerned about the limitations of the battery or AC power, install both types of alarms.

CO/NATURAL GAS alarms are designed to detect carbon monoxide and natural gases from any source
of combustion or natural gas leakage that reaches their sensor.

USING AN IONIZATION SMOKE ALARM IN A SMOKY AREA, SUCH AS A KITCHEN, OR IN A HIGH
HUMIDITY AREA NEAR A SHOWER, CAN CAUSE NUISANCE FALSE ALARMS. IT IS PREFERABLE
TO USE PHOTOELECTRIC ALARMS IN THESE AREAS. DO NOT TURN OFF THE AC POWER TO
QUIET THE ALARM. A SMOKE ALARM WILL NOT HELP PROTECT YOU IF IT IS NOT POWERED.
Properly locate your alarm to avoid nuisance alarms.

A SMOKE ALARM MAY NOT ALWAYS WARN YOU ABOUT FIRES CAUSED BY CARELESSNESS
AND SAFETY HAZARDS LIKE SMOKING IN BED, VIOLENT EXPLOSIONS, ESCAPING GAS,
IMPROPER STORAGE OF FLAMMABLE MATERIALS, OVERLOADED ELECTRICAL CIRCUITS,
CHILDREN PLAYING WITH MATCHES, NATURAL CAUSES SUCH AS LIGHTNING, OR ARSON. FIRE
PREVENTION IS YOUR BEST SAFEGUARD.

INSTALLING SMOKE ALARMS MAY MAKE YOU ELIGIBLE FOR LOWER INSURANCE RATES, BUT
SMOKE ALARMS ARE NOT A SUBSTITUTE FOR INSURANCE. Homeowners and renters alike should
continue to insure their lives and properties.

SMOKE ALARMS CANNOT DETECT FIRES IF THE SMOKE DOES NOT REACH THEM. 

 

 Smoke from

fires may not reach the sensing chamber and set off the alarm. One alarm should be installed inside each
bedroom or sleeping area. Do not obstruct airflow around the smoke alarm or place in areas of obstructed
airflow.

BE AWARE OF VARIOUS SITUATIONS AGAINST WHICH THE SMOKE ALARM MAY NOT BE
EFFECTIVE. For example: (1) Fires where the victim is intimate with a flaming initiated fire; for example,
when a person's clothes catch fire while cooking; (2) Fires where the smoke is prevented from reaching
the alarm due to a closed door or other obstruction or (3) Incendiary fires where the fire grows so rapidly
that an occupant's egress is blocked even with properly located alarms.
SMOKE ALARMS MAY NOT DETECT FIRE ON ANOTHER FLOOR OR AREA OF THE HOME.
Recommended minimum protection is at least one smoke alarm in every sleeping area and every bedroom
on every level of your home. Interconnected smoke alarms may provide earlier warning than stand-alone
smoke alarms since all smoke alarms alarm when one detects smoke.

SMOKE ALARMS MAY NOT BE HEARD. The alarm horn in this alarm meets or exceeds current  standards,
but it may not be heard if: (1) the smoke alarm is located outside a closed or partially closed door; (2)
residents recently consumed alcohol or drugs; (3) the alarm is drowned out by noise from stereos, TV's,
air conditioners or other appliances; (4) residents are hearing impaired or (5) if residents are sleeping.
CURRENT STUDIES HAVE SHOWN SMOKE ALARMS MAY NOT AWAKEN ALL SLEEPING
INDIVIDUALS AND THAT IT IS THE RESPONSIBILITY OF INDIVIDUALS IN THE HOUSEHOLD WHO
ARE CAPABLE OF ASSISTING OTHERS TO PROVIDE ASSISTANCE TO THOSE WHO MAY NOT BE
AWAKENED BY THE ALARM SOUND OR TO THOSE WHO MAY BE INCAPABLE OF SAFELY
EVACUATING THE AREA UNASSISTED.

SMOKE ALARMS ARE NOT FOOLPROOF

 You must test the smoke alarm weekly to ensure your

continued protection. Smoke alarms cannot prevent or extinguish fires.

COMBINATION CO/NATURAL GAS/SMOKE ALARMS HAVE A LIMITED LIFE. The Combination CO/
Natural Gas/Smoke alarm should be replaced immediately if it is not operating properly. You should
always replace a Combination CO/Natural Gas/Smoke alarm after 7 years.

SMOKE ALARMS ARE NOT TO BE USED WITH DETECTOR GUARDS UNLESS THE COMBINATION
HAS BEEN EVALUATED AND FOUND SUITABLE FOR THAT PURPOSE.

Page2

Summary of Contents for MICN102

Page 1: ...C 60 Hz 100 mAMax SECURITY INSTRUMENTS INC Table of Contents Page Alarm Limitations and Functions 2 What You Should Know About CO 3 What You Should Know About Natural Gas 3 Basic Safety Information 5...

Page 2: ...SIONS ESCAPING GAS IMPROPER STORAGE OF FLAMMABLE MATERIALS OVERLOADED ELECTRICAL CIRCUITS CHILDREN PLAYING WITH MATCHES NATURAL CAUSES SUCH AS LIGHTNING OR ARSON FIRE PREVENTION IS YOUR BEST SAFEGUARD...

Page 3: ...ical problems may consider using warning devices which provide audible and visual warnings for carbon monoxide concentrations under 30 ppm IMPORTANT CONSIDERATIONS YOUR COMBINATION SMOKE CO AND NATURA...

Page 4: ...ceiling shall be located within 36 in 914 mm horizontally of the peak but not closer than 4 in 102 mm vertically to the peak Sloped Ceilings Shed Ceilings Smoke alarms or combination alarms mounted on...

Page 5: ...to detect any other gas Carbon monoxide and natural gas may be present in other areas The Smoke CO and Natural Gas Alarm will only indicate the presence of CO or natural gas which reaches the sensor D...

Page 6: ...nted alarms can occur if an alarm is placed directly next to a fuel burning source Ventilate these areas as much as possible If you must install the alarm near a cooking or heating appliance install a...

Page 7: ...e alarm in the direction indicated by the TWIST TO REMOVE arrow on the side of the alarm base OPTIONAL TAMPER RESISTANT FEATURES There are two separate tamper resistant locking features provided for t...

Page 8: ...sing models within an interconnected system The following alarms cannot reset units on an interconnected system USI 7795 CD 9795 USI 7385 USI 7390 USI 7485 USI 7490 CD 9385 CD 9390 CD 9485 CD 9490 The...

Page 9: ...rm utilizes battery backup power the natural gas sensor will operate the alarm and will sample less frequently to extend battery life Natural gas could be present during this period between samples wi...

Page 10: ...ach alarm event TESTING Test by pushing the Test button on the alarm cover until the alarm sounds then release The alarm will sound 3 beeps approx 2 second pause 3 beeps approx 6 second pause 4 beeps...

Page 11: ...etected If CO levels drop below alarm levels the alarm will remain silent and return to normal operation If CO levels remain constant or increase this indicates a potentially dangerous situation and t...

Page 12: ...y damage or set fire to the alarm or to your home The built in test switch accurately tests the unit s operation as required by the UL 217 UL 2034 and UL 1484 Standards NEVER use vehicle exhaust Exhau...

Page 13: ...self diagnostic test reveals a malfunction immediately have the unit replaced see last page for warranty information Smoke CO and Natural Gas alarms can only sense CO which reaches the alarm s sensor...

Page 14: ...nsumer is exempt from any licensing or requirements Simultaneous operation of several fuel burning appliances competing for limited internal air Vent pipe connections vibrating loose from clothes drye...

Page 15: ...sleeping area within 6 4 m 21 ft of any door to a sleeping room the distance measured along a path of travel 3 On every level of a dwelling unit including basements 4 On every level of a residential...

Page 16: ...ff Blinks On in sync with the 1 beep Condition Originating GAS Alarm Recommendation If hazard is identified take all precautions if an alarm sounds by calling an Emergency Service and getting out of t...

Page 17: ...enced for a 10 hour period for up to 20 days After 20 days the warning cannot be silenced The alarm should be replaced immediately Silent alarmed previously Off and Blinks On approx every 5 seconds un...

Page 18: ...ECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE LAW SHALL...