5.3.4 Power on failure in Initializing
If power turns off a few seconds after Robot Power is turned On in the Initializing window, there are many
possible causes for this phenomenon.
Most likely it is a control box failure or a communication failure with a joint or the tool.
Control box failure
Replace 48V power supply
During power up (within the first three seconds of
power up) measure that 230V AC is present on
48V_PSU1 connector on current distributor PCB
Power controller OFF/ON
Measure that 12V DC is present in the red
connector/flatcable on the current distributor
Replace current distributor
Check log history for error messages and consult
the section Error Codes for detailed explanation
Replace Safety Control
Board
YES
YES
NO
NO
Summary of Contents for ur3
Page 96: ...All rights reserved 96 Servicemanual_UR3_en_rev3 1 2 ...
Page 97: ...All rights reserved 97 Servicemanual_UR3_en_rev3 1 2 ...
Page 98: ...All rights reserved 98 Servicemanual_UR3_en_rev3 1 2 ...
Page 99: ...All rights reserved 99 Servicemanual_UR3_en_rev3 1 2 ...
Page 101: ...All rights reserved 101 Servicemanual_UR3_en_rev3 1 2 ...
Page 102: ...All rights reserved 102 Servicemanual_UR3_en_rev3 1 2 ...
Page 103: ...All rights reserved 103 Servicemanual_UR3_en_rev3 1 2 ...
Page 104: ...All rights reserved 104 Servicemanual_UR3_en_rev3 1 2 ...
Page 105: ...All rights reserved 105 Servicemanual_UR3_en_rev3 1 2 ...
Page 106: ...All rights reserved 106 Servicemanual_UR3_en_rev3 1 2 ...
Page 107: ...All rights reserved 107 Servicemanual_UR3_en_rev3 1 2 ...
Page 108: ...All rights reserved 108 Servicemanual_UR3_en_rev3 1 2 ...
Page 109: ...All rights reserved 109 Servicemanual_UR3_en_rev3 1 2 ...
Page 110: ...All rights reserved 110 Servicemanual_UR3_en_rev3 1 2 ...
Page 111: ...All rights reserved 111 Servicemanual_UR3_en_rev3 1 2 ...
Page 112: ...All rights reserved 112 Servicemanual_UR3_en_rev3 1 2 ...