Servicemanual_UR3_en_rev3.1.2
5.3 Error phenomena
5.3.1 ControlBox: NO CONTROLLER displayed in Initializing
ControlBox = NO
CONTROLLER displayed at
INITIALIZING screen
Defective Safety Control
Board
Replace Safety Control Board and verify problem
is solved
Replace Ethernet cable between motherboard
and Safety Control Board and verify problem is
solved
Replace motherboard and verify problem is solved
Defective motherboard
YES
YES
NO
NO
Defective Ethernet cable
YES
Summary of Contents for ur3
Page 96: ...All rights reserved 96 Servicemanual_UR3_en_rev3 1 2 ...
Page 97: ...All rights reserved 97 Servicemanual_UR3_en_rev3 1 2 ...
Page 98: ...All rights reserved 98 Servicemanual_UR3_en_rev3 1 2 ...
Page 99: ...All rights reserved 99 Servicemanual_UR3_en_rev3 1 2 ...
Page 101: ...All rights reserved 101 Servicemanual_UR3_en_rev3 1 2 ...
Page 102: ...All rights reserved 102 Servicemanual_UR3_en_rev3 1 2 ...
Page 103: ...All rights reserved 103 Servicemanual_UR3_en_rev3 1 2 ...
Page 104: ...All rights reserved 104 Servicemanual_UR3_en_rev3 1 2 ...
Page 105: ...All rights reserved 105 Servicemanual_UR3_en_rev3 1 2 ...
Page 106: ...All rights reserved 106 Servicemanual_UR3_en_rev3 1 2 ...
Page 107: ...All rights reserved 107 Servicemanual_UR3_en_rev3 1 2 ...
Page 108: ...All rights reserved 108 Servicemanual_UR3_en_rev3 1 2 ...
Page 109: ...All rights reserved 109 Servicemanual_UR3_en_rev3 1 2 ...
Page 110: ...All rights reserved 110 Servicemanual_UR3_en_rev3 1 2 ...
Page 111: ...All rights reserved 111 Servicemanual_UR3_en_rev3 1 2 ...
Page 112: ...All rights reserved 112 Servicemanual_UR3_en_rev3 1 2 ...