V350-35-T2 Installation Guide

2

Unitronics 

Standard Kit Contents 

Vision controller 

Mounting brackets (x2) 

I/O connectors (x2) 

Rubber seal 

Battery (installed) 

2 sets of key label slides  

Programming cable + RS232 adapter 

Unitronics’ Setup CD 

 

Danger Symbols 

When any of the following symbols appear, read the associated information carefully. 
Symbol Meaning  Description 

Danger 

The identified danger causes physical and property damage. 

Warning 

The identified danger could cause physical and property damage. 

Caution

 Caution  Use 

caution. 

Before using this product, the user must read and understand this document.  
All examples and diagrams are intended to aid understanding, and do not guarantee operation. 
Unitronics accepts no responsibility for actual use of this product based on these examples. 
Please dispose of this product according to local and national standards and regulations. 
Only qualified service personnel should open this device or carry out repairs. 

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.

Do not attempt to use this device with parameters that exceed permissible levels. 
To avoid damaging the system, do not connect/disconnect the device when power is on. 

Environmental Considerations 

Do not install in areas with: excessive or conductive dust, corrosive or flammable gas,  
moisture or rain, excessive heat, regular impact shocks or excessive vibration, in accordance 
with the standards given in the product’s technical specification sheet. 
Ventilation: 10mm space required between controller’s top/bottom edges & enclosure walls. 
Do not place in water or let water leak onto the unit. 
Do not allow debris to fall inside the unit during installation. 
Install at maximum distance from high-voltage cables and power equipment. 

Summary of Contents for Vision V350-35-T2

Page 1: ...al I Os Information Mode This mode enables you to View Edit operand values COM port settings RTC and screen contrast brightness settings Calibrate the touchscreen Stop initialize and reset the PLC To enter Information Mode press the i button for several seconds Programming Software Utilities The Unitronics Setup CD contains VisiLogic software and other utilities VisiLogic Easily configure hardware...

Page 2: ...lease dispose of this product according to local and national standards and regulations Only qualified service personnel should open this device or carry out repairs Failure to comply with appropriate safety guidelines can cause severe injury or property damage Do not attempt to use this device with parameters that exceed permissible levels To avoid damaging the system do not connect disconnect th...

Page 3: ...oller into the cut out ensuring that the rubber seal is in place 3 Push the 2 mounting brackets into their slots on the sides of the controller as shown in the figure to the right 4 Tighten the bracket screws against the panel Hold the bracket securely against the unit while tightening the screw 5 When properly mounted the controller is squarely situated in the panel cut out as shown in the figure...

Page 4: ... m 5 kgf cm Do not use tin solder or any substance on stripped wire that might cause the wire strand to break Install at maximum distance from high voltage cables and power equipment Use crimp terminals for wiring use 26 12 AWG wire 0 13 mm 2 3 31 mm2 1 Strip the wire to a length of 7 0 5mm 0 250 0 300 inches 2 Unscrew the terminal to its widest position before inserting a wire 3 Insert the wire c...

Page 5: ...nd 5 can function as either counter reset as normal digital inputs or as part of a shaft encoder Input Jumper Settings The tables below show how to set a specific jumper to change input functionality To access the I O jumpers you must open the controller according to the instructions beginning on page 9 Incompatible jumper settings and wiring connections may seriously damage the controller Do not ...

Page 6: ...p source HSC input wiring npn sink HSC input wiring pnp source Shaft encoder Analog input wiring voltage current 4 wire Analog input wiring current 2 3 wire Shields should be connected at the signal s source The 0V signal of the analog input must be connected to the controller s 0V ...

Page 7: ...Neutral or Line signal of the 110 220VAC to device s 0V pin In the event of voltage fluctuations or non conformity to voltage power supply specifications connect the device to a regulated power supply Earthing the Power Supply To maximize system performance avoid electromagnetic interference by Mounting the controller on a metal panel Earthing the controller s power supply connect one end of a 14 ...

Page 8: ...S485 remove the RS485 connector and connect the PC to the PLC via the programming cable Note that this is possible only if flow control signals are not used which is the standard case RS232 RS485 Controller Port Pin Description Pin Description 1 DTR signal 1 A signal 2 0V reference 2 RS232 signal 3 TXD signal 3 RS232 signal 4 RXD signal 4 RS232 signal 5 0V reference 5 RS232 signal 6 DSR signal 6 B...

Page 9: ...the controller comprises 4 screws located in the corners Remove the screws and pull off the back cover Changing I O settings 1 The I O board of the controller is now exposed enabling you to change I O settings according to the jumpers shown on page 5 Changing Communication settings 1 To access the communication jumpers hold the I O PCB board by its top and bottom connectors and steadily pull the b...

Page 10: ...rarily withdraw any of the forgoing from the market All information in this document is provided as is without warranty of any kind either expressed or implied including but not limited to any implied warranties of merchantability fitness for a particular purpose or non infringement Unitronics assumes no responsibility for errors or omissions in the information presented in this document In no eve...

Reviews: