V350-35-T2 Installation Guide

10 

 Unitronics 

Closing the Controller

1. Gently replace the board.  Make 

certain that the pins fit correctly 
into their matching receptacle.  
Do not force the board into place; 
doing so may damage the 
controller. 

2. Replace the back cover of the 

controller and fasten the corner 
screws. 

Note that you must replace the back cover securely before powering up the controller. 

 

The information in this document reflects products at the date of printing. Unitronics reserves the right, subject to all applicable laws, at any time, at its sole 

discretion, and without notice, to discontinue or change the features, designs, materials and other specifications of its products, and to either permanently or 

temporarily withdraw any of the forgoing from the market. 
All information in this document is provided "as is" without warranty of any kind, either expressed or implied, including but not limited to any implied warranties of 

merchantability, fitness for a particular purpose, or non-infringement. Unitronics assumes no responsibility for errors or omissions in the information presented in 
this document. In no event shall Unitronics be liable for any special, incidental, indirect or consequential damages of any kind, or any damages whatsoever arising 

out of or in connection with the use or performance of this information. 
The tradenames, trademarks, logos and service marks presented in this document, including their design, are the property of Unitronics (1989) (R"G) Ltd. or other 
third parties and you are not permitted to use them without the prior written consent of Unitronics or such third party as may own them

 

DIG-V350-T2 12/07

 

Summary of Contents for Vision V350-35-T2

Page 1: ...al I Os Information Mode This mode enables you to View Edit operand values COM port settings RTC and screen contrast brightness settings Calibrate the touchscreen Stop initialize and reset the PLC To enter Information Mode press the i button for several seconds Programming Software Utilities The Unitronics Setup CD contains VisiLogic software and other utilities VisiLogic Easily configure hardware...

Page 2: ...lease dispose of this product according to local and national standards and regulations Only qualified service personnel should open this device or carry out repairs Failure to comply with appropriate safety guidelines can cause severe injury or property damage Do not attempt to use this device with parameters that exceed permissible levels To avoid damaging the system do not connect disconnect th...

Page 3: ...oller into the cut out ensuring that the rubber seal is in place 3 Push the 2 mounting brackets into their slots on the sides of the controller as shown in the figure to the right 4 Tighten the bracket screws against the panel Hold the bracket securely against the unit while tightening the screw 5 When properly mounted the controller is squarely situated in the panel cut out as shown in the figure...

Page 4: ... m 5 kgf cm Do not use tin solder or any substance on stripped wire that might cause the wire strand to break Install at maximum distance from high voltage cables and power equipment Use crimp terminals for wiring use 26 12 AWG wire 0 13 mm 2 3 31 mm2 1 Strip the wire to a length of 7 0 5mm 0 250 0 300 inches 2 Unscrew the terminal to its widest position before inserting a wire 3 Insert the wire c...

Page 5: ...nd 5 can function as either counter reset as normal digital inputs or as part of a shaft encoder Input Jumper Settings The tables below show how to set a specific jumper to change input functionality To access the I O jumpers you must open the controller according to the instructions beginning on page 9 Incompatible jumper settings and wiring connections may seriously damage the controller Do not ...

Page 6: ...p source HSC input wiring npn sink HSC input wiring pnp source Shaft encoder Analog input wiring voltage current 4 wire Analog input wiring current 2 3 wire Shields should be connected at the signal s source The 0V signal of the analog input must be connected to the controller s 0V ...

Page 7: ...Neutral or Line signal of the 110 220VAC to device s 0V pin In the event of voltage fluctuations or non conformity to voltage power supply specifications connect the device to a regulated power supply Earthing the Power Supply To maximize system performance avoid electromagnetic interference by Mounting the controller on a metal panel Earthing the controller s power supply connect one end of a 14 ...

Page 8: ...S485 remove the RS485 connector and connect the PC to the PLC via the programming cable Note that this is possible only if flow control signals are not used which is the standard case RS232 RS485 Controller Port Pin Description Pin Description 1 DTR signal 1 A signal 2 0V reference 2 RS232 signal 3 TXD signal 3 RS232 signal 4 RXD signal 4 RS232 signal 5 0V reference 5 RS232 signal 6 DSR signal 6 B...

Page 9: ...the controller comprises 4 screws located in the corners Remove the screws and pull off the back cover Changing I O settings 1 The I O board of the controller is now exposed enabling you to change I O settings according to the jumpers shown on page 5 Changing Communication settings 1 To access the communication jumpers hold the I O PCB board by its top and bottom connectors and steadily pull the b...

Page 10: ...rarily withdraw any of the forgoing from the market All information in this document is provided as is without warranty of any kind either expressed or implied including but not limited to any implied warranties of merchantability fitness for a particular purpose or non infringement Unitronics assumes no responsibility for errors or omissions in the information presented in this document In no eve...

Reviews: