background image

 

Unitronics 

 

 

Uni-I/O™ Modules 

  Installation Guide 
  UIS-04PTN, UIS-04PTKN 

Uni-I/O™ is a family of Input/Output modules that are compatible with the UniStream™ 

control platform.  

This guide provides basic installation information for the UIS-04PTN and UIS-04PTKN 

module.  

Technical specifications may be downloaded from the Unitronics website. 
The UniStream™ platform 

comprises CPU controllers, HMI 

panels, and local I/O modules  

that snap together to form an  

all-in-one Programmable Logic 

Controller (PLC).  
Install Uni-I/O™ modules: 

 

Onto the back of any 

UniStream™ HMI Panel 

comprising a CPU-for-Panel. 

 

Onto a DIN-rail, using a  

Local Expansion Kit. 

 

 

The maximum number of Uni-I/O™ modules that can be connected to a single CPU 

controller is limited. For details, please refer to the specification sheets of the UniStream™ 

CPU or any of the relevant Local Expansion Kits. 

Before You Begin 

 

 

Before installing the device, the installer must: 

 

Read and understand this document. 

 

Verify the Kit Contents.  

Installation option requirements 

If you are installing a Uni-I/O™ module onto: 

 

A UniStream™ HMI Panel; the Panel must comprise a CPU-for-Panel, installed according 

to the CPU-for-Panel installation guide. 

 

A DIN-rail; you must use a Local Expansion Kit, available by separate order, to integrate 
the Uni-I/O™ modules on the DIN-rail into a UniStream™ control system. 

 

Alert Symbols and General Restrictions 

When any of the following symbols appear, read the associated information carefully. 

Symbol 

Meaning 

Description 

 

Danger 

The identified danger causes physical and property damage. 

 

Warning 

The identified danger could cause physical and property damage. 

Caution 

Caution 

Use caution. 

 

All examples and diagrams are intended to aid understanding, and do not guarantee 

operation. Unitronics accepts no responsibility for actual use of this product based on 

these examples. 

 

Please dispose of this product according to local and national standards and regulations. 

 

This product should be installed only by qualified personnel. 

 

Summary of Contents for Uni-I/O UIS-04PTKN

Page 1: ...evice the installer must Read and understand this document Verify the Kit Contents Installation option requirements If you are installing a Uni I O module onto A UniStream HMI Panel the Panel must comprise a CPU for Panel installed according to the CPU for Panel installation guide A DIN rail you must use a Local Expansion Kit available by separate order to integrate the Uni I O modules on the DIN ...

Page 2: ...al specification sheet Do not place in water or let water leak onto the unit Do not allow debris to fall inside the unit during installation Install at maximum distance from high voltage cables and power equipment Kit Contents 1 Uni I O module 2 I O terminal blocks black Uni I O Diagram 1 DIN rail clips Provide physical support for CPU and modules There are two clips one at the top shown one at th...

Page 3: ...ution If the I O module is located last in the configuration and nothing is to be connected to it do not remove its Bus Connector Cover Installation Turn off system power before connecting or disconnecting any modules or devices Use proper precautions to prevent Electro Static Discharge ESD Installing a Uni I O Module onto a UniStream HMI Panel NOTE The DIN rail type structure on the back of the p...

Page 4: ...i I O modules onto a DIN rail To mount modules onto a DIN rail follow steps 1 7 in Installing a Uni I O Module onto a UniStream HMI Panel on page 3 In order to connect the modules to a UniStream controller you must use a Local Expansion Kit These kits are available with and without power supplies and with cables of varying lengths For complete information please refer to the installation guide of ...

Page 5: ...refer to the Uni I O connection points These points are arranged in two groups of 2 points as shown in the figure to the right Top group Input connection points 0 1 Bottom group Input connection points 2 3 Wiring Guidelines In order to ensure that the device will operate properly and to avoid electromagnetic interference Use a metal cabinet Make sure the cabinet and its doors are properly earthed ...

Page 6: ...ifications of its products and to either permanently or temporarilywithdraw anyof the forgoing from the market All information in this document isprovided as is withoutwarranty of any kind either expressedor implied including but not limited to any impliedwarranties of merchantability fitness for aparticular purpose or non infringement Unitronicsassumes no responsibility for errors or omissions in...

Page 7: ...aller must Read and understand this document Verify the Kit Contents Installation option requirements If you are installing a Uni I O module onto A UniStream HMI Panel the Panel must comprise a CPU for Panel installed according to the CPU for Panel installation guide A DIN rail you must use a Local Expansion Kit available by separate order to integrate the Uni I O modules on the DIN rail into a Un...

Page 8: ... technical specification sheet Do not place in water or let water leak onto the unit Do not allow debris to fall inside the unit during installation Install at maximum distance from high voltage cables and power equipment Kit Contents 1 UIS 08TC module 4 I O terminal blocks 2 black and 2 gray UIS 08TC Diagram 1 DIN rail clips Provide physical support for CPU and modules There are two clips one at ...

Page 9: ...e Unit of the Local Expansion Kit Caution If the I O module is located last in the configuration and nothing is to be connected to it do not remove its Bus Connector Cover Installation Turn off system power before connecting or disconnecting any modules or devices Use proper precautions to prevent Electro Static Discharge ESD Installing a Uni I O Module onto a UniStream HMI Panel NOTE The DIN rail...

Page 10: ...O modules onto a DIN rail To mount modules onto a DIN rail follow steps 1 7 in Installing a Uni I O Module onto a UniStream HMI Panel on page 3 In order to connect the modules to a UniStream controller you must use a Local Expansion Kit These kits are available with and without power supplies and with cables of varying lengths For complete information please refer to the installation guide of the ...

Page 11: ...om pulling free UIS 08TC Connection Points All wiring diagrams and instructions in this document refer to the UIS 08TC connection points These points are arranged in four groups of seven points as shown in the figure to the right Two top groups Input connection points 0 1 2 3 Two bottom groups Input connection points 4 5 6 7 and power supply connection points Wiring Guidelines In order to ensure t...

Page 12: ...iguration within the software application The information in this documentreflects products at the date of printing Unitronics reserves the right subject to allapplicable laws at any time at its sole discretion and without notice to discontinue or change the features designs materialsand otherspecifications of its products and to either permanently or temporarily withdraw any of the forgoing from ...

Reviews: