 Installation Guide 

 

JZ20-R31/JZ20-J-R31 

16 Digital, 2 Analog/Digital, 2 Analog Inputs, 11 Relay Outputs 

  Before using this product, the user must read and understand this document.  

  For additional information regarding this product, refer to the user guide and technical specifications. 

  All examples and diagrams are intended to aid understanding, and do not guarantee operation.  

Unitronics accepts no responsibility for actual use of this product based on these examples. 

  Please dispose of this product according to local and national standards and regulations. 

  Only qualified service personnel should open this device or carry out repairs. 

 

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.  

 

  Do not attempt to use this device with parameters that exceed permissible levels. 

  To avoid damaging the system, do not connect/disconnect the device when power is on. 

Environmental Considerations 

 

  Do not install in areas with: excessive or conductive dust, corrosive or flammable gas,  

moisture or rain, excessive heat, regular impact shocks or excessive vibration. 

 

  Ventilation: 10mm space required between the O

PLCs’ top/bottom edges & enclosure walls. 

  Do not place in water or let water leak onto the unit. 

  Do not allow debris to fall inside the unit during installation. 

 

Mounting 

Dimensions 

 

 

* Note that for JZ20-J modules those dimensions are 7.5 mm (0.295

”).

 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for JZ20-J-R31

Page 1: ... personnel should open this device or carry out repairs Failure to comply with appropriate safety guidelines can cause severe injury or property damage Do not attempt to use this device with parameters that exceed permissible levels To avoid damaging the system do not connect disconnect the device when power is on Environmental Considerations Do not install in areas with excessive or conductive du...

Page 2: ...odule in order to meet the UL508 standard panel mount this device on the flat surface of a Type 1 enclosure Wiring Note All diagrams are based on the rear view of the OPLC This equipment is designed to operate only in SELV PELV Class 2 Limited Power environments All power supplies in the system must include double insulation Power supply outputs must be rated as SELV PELV Class 2 Limited Power Do ...

Page 3: ...ross the ducts at a 90 angle For proper system operation all 0V points in the system should be connected to the system 0V supply rail Allow for voltage drop and noise interference with input lines used over an extended distance Use wire that is properly sized for the load Earthing the JZ20 R31 JZ20 J R31 To maximize system performance avoid electromagnetic interference as follows Use a metal cabin...

Page 4: ...puts are arranged in two groups You can wire one group as npn and the other as pnp or wire both groups as npn or as pnp In either case the npn pnp pins must be connected Input wiring npn sink Input wiring pnp source Input wiring I0 I15 pnp source I16 I17 npn sink Digital Outputs Output wiring ...

Page 5: ...ing diode in parallel with each inductive DC load An RC snubber circuit in parallel with each inductive AC load Analog inputs Note Shields should be connected at the signal source Analog Input wiring current AN0 AN1 2 or 3 wire 4 wire Analog Input wiring voltage AN2 AN3 Note If either I16 or I17 is wired as an npn digital input the remaining input may not be wired as an analog input ...

Page 6: ... limited to any implied warranties of merchantability fitness for a particular purpose or non infringement Unitronics assumes no responsibility for errors or omissions in the information presented in this document In no event shall Unitronics be liable for any special incidental indirect or consequential damages of any kind or any damages whatsoever arising out of or in connection with the use or ...

Reviews: