OM-244 324 Page 18
4-4.
Stick Start Procedure
−
Scratch Start Technique
With Stick selected, start arc as follows:
1
Electrode
2
Workpiece
3
Arc
Drag electrode across workpiece like strik-
ing a match; lift electrode slightly after touch-
ing work. If arc goes out electrode was lifted
to high. If electrode sticks to workpiece, use
a quick twist to free it.
Y
For models with stock number 907
220, normal open-circuit voltage (80
volts) is present before electrode
touches workpiece.
For models with stock numbers 907 036 and
907 037, normal open-circuit voltage is not
present before electrode touches work-
piece; only a low sensing voltage is present
between electrode and workpiece.
1
2
3
4-5. Amperage Control
1
A (Amperage Control)
Rotate knob clockwise to increase
amperage (Min-200 amps).
1
Min
4-6. DIG Control
1
DIG Control
Control increases SMAW short-cir-
cuit amperage at low arc voltage.
This allows the operator to use a
very short arc length without stick-
ing the electrode.
Set control at 0 for normal welding
amperage. Turn clockwise to in-
crease short-circuit amperage.
1